Firetox Flame Retardant Cables | |||
Flame Retardant Data Cables
Flame Retardant CAT5e CWB/SWB/SWA Armoured Data CablesFTX-CAT5e U/UTP4P24 cwb/swb/swa
|
Flame Retardance (Single Vertical |
EN 60332-1-2; IEC 60332-1-2; BS EN 60332-1-2; VDE |
Reduced Fire Propagation |
EN 60332-3-24 (cat. C); IEC 60332-3-24; BS EN 60332-3-24; VDE 0482-332-3; NBN C 30-004 (cat. F2); NF C32-070-2.2(C1); CEI 20-22/3-4; EN 50266-2-4*; DIN VDE 0482-266-2-4 |
Halogen Free |
IEC 60754-1; EN 50267-2-1; DIN VDE 0482-267-2-1; CEI 20-37/2-1 ; BS 6425-1* |
No Corrosive Gas Emission |
IEC 60754-2; EN 50267-2-2; DIN VDE 0482-267-2-2; CEI 20-37/2-2 ; BS 6425-2* |
minimum Smoke Emission |
IEC 61034-1&2; EN 61034 -1&2; DIN VDE 0482-1034-1&2; CEI 20-37/3-1&2; EN 50268-1&2*; BS 7622-1&2* |
No Toxic gases |
NES 02-713; NF C 20-454 |
Note: Asterisk * denotes superseded standard.
VOLTAGE RATING
60V
CABLE CONSTRUCTION
Conductors: 24AWG solid bare copper.
Insulation: HDPE.
Twinning: Two coloured insulated conductors twisted together to form a pair.
Inner Sheath: Flame retardant, low smoke and halogen-free polyolefin, coloured black.
Armouring:
cwb: copper Wire Braid
swb: Steel Wire Braid
swa: Steel Wire Armour
Outer Sheath: Thermoplastic LSZH compound type LTS3 as per BS 7655-6.1 (Thermosetting
LSZH compound type SW2-SW4 as per BS 7655:section 2.6 can be offered.)
Cat5E F/UTP: These cables have collective shielding of aluminium/Polyester tape with drain wire.
Cat5E SF/UTP: These cables have double collective shieldings of aluminium/Polyester tape &
copper wire braid.
Physical AND THERMAL PROPERTIES
Temperature range: -30°C ~ +75°C
Minimum bending radius during installation (mobile state): 8 x Overall Diameter
Minimum bending radius during operation (fixed state): 4 x Overall Diameter
Electrical Properties
AWG |
|
24 |
Nominal Conductor Diameter |
mm |
0.53 |
maximum DC Resistant@20°C |
Ω/100m |
9.38 |
maximum DCR Unbalance |
% |
5 |
maximum mutual Capacitance |
pF/m |
55.8 |
maximum Capacitance Unbalance |
pF/100m |
330 |
Characteristic Impedance@1-100mHz |
Ω |
100+/-15 |
maximum Propagation Delay Skew |
ns/100m |
45 |
Transmission Properties
FREQ |
maximum |
minimum |
minimum |
minimum |
minimum |
minimum |
0.772 |
1.8 |
67.0 |
64.0 |
66.0 |
63.0 |
— |
1 |
2.0 |
65.3 |
62.3 |
63.8 |
60.8 |
20.0 |
4 |
4.1 |
56.3 |
53.3 |
51.7 |
48.7 |
23.0 |
8 |
5.8 |
51.8 |
48.8 |
45.7 |
42.7 |
24.5 |
10 |
6.5 |
50.3 |
47.3 |
43.8 |
40.8 |
25.0 |
16 |
8.2 |
47.3 |
44.3 |
39.7 |
36.7 |
25.0 |
20 |
9.3 |
45.8 |
42.8 |
37.7 |
34.7 |
25.0 |
25 |
10.4 |
44.3 |
41.3 |
35.8 |
32.8 |
24.3 |
31.25 |
11.7 |
42.9 |
39.9 |
33.9 |
30.9 |
23.6 |
62.5 |
17.0 |
38.4 |
35.4 |
27.8 |
24.8 |
21.5 |
100 |
22.0 |
35.3 |
32.3 |
23.8 |
20.8 |
20.1 |
Cat5E SF/UTP
CONSTRUCTION PARAMETERS
Cable Code |
Construction |
Nominal Insulation Thickness |
Nominal Inner Sheath Thickness |
Nominal Outer Sheath Thickness |
Nominal Overall Diameter |
Nominal |
|
mm |
mm |
mm |
mm |
mm |
kg/km |
caT5e U/UTP cWb |
4×2×0.53 |
0.2 |
0.6 |
1.0 |
7.68 |
97 |
caT5e U/UTP sWb |
4×2×0.53 |
0.2 |
0.6 |
1.0 |
7.68 |
93 |
caT5e U/UTP sWa |
4×2×0.53 |
0.2 |
0.6 |
1.0 |
8.68 |
165 |
caT5e f/UTP cWb |
4×2×0.53 |
0.2 |
0.6 |
1.0 |
8.28 |
116 |
caT5e f/UTP sWb |
4×2×0.53 |
0.2 |
0.6 |
1.0 |
8.28 |
112 |
caT5e f/UTP sWa |
4×2×0.53 |
0.2 |
0.6 |
1.0 |
9.28 |
192 |
caT5e sf/UTP cWb |
4×2×0.53 |
0.2 |
0.6 |
1.0 |
8.76 |
123 |
caT5e sf/UTP sWb |
4×2×0.53 |
0.2 |
0.6 |
1.0 |
8.76 |
119 |
caT5e sf/UTP sWa |
4×2×0.53 |
0.2 |
0.6 |
1.0 |
9.76 |
216 |