Home
Chi siamo
Prodotti
Scaricare
Biblioteca tecnica
Contatto
Richiesta
Mappa del sito 
Collegamenti
 

Allarme & Cavo Audio & Elettronico

Cavo di Equivalente di Belden

Cavo coassiale

Cavo di Controllo

Cavo Fibra Ottica

Cavo Flessibile

Cavo strumentazione

Cavi LAN
Cavo Energia
CavoFerroviario

Robotic

Cavo per Materiale Rotabile
Cavo di gomma
Cavo di Sicurezza

Cavo Telefonico

Aeroporto Cavo

Bus Cavo

Serracavi

Data Cable

Calore di rilevamento Cavo
Cavo ad alta temperatura
Cavo autostrada
Marine, petrolio, gas e petrolchimico Cavo
Cavo Speciali
Cavo a spirale
Termocoppia Cavo
     
  indoor tight buffer fiber optic cable  
Indoor Used Tight Buffered Fiber
Optical Cable
outdoor multi loose tube fiber optic cable
Outdoor Used Multi Loose Tube
Fiber Optical Cable
 
  Bus Cavo 
Profibus DP Profibus PA Profibus SK Foundation Field Bus

Bus Cavo

Profibus L2-Torsion + Festoon

Applicazione:

The series TORSION and FESTOON are used to interconnect Profibus BUS components. This BUS system is a very economical solution for the field area. For the information exchange between different automation systems as well as for communication with the connected decentralized field units, serial field bus systems are used. The lines described here are designed torsionable or hanging movable construction. Areas such as robot applications and/or garland suspension are easily realized.

Costruzione:

Type/Area of Application

Torsion Applications

Mobile Use

Cable Construction

1x2x0.64 mm (stranded)

1x2x0.65 mm (stranded)

Inner Conductor Diameter 1

Copper, bare (AWG 23/19)

Copper, bare (AWG 24/19)

Conductor Insulation

Foam-skin-PE

Cell PE

Conductor Colors

red, green

red, green

Stranding Element

2 conductors + 2 fillers stranded together

2 conductors + 2 fillers stranded together

Shielding 1

Polyester foil over stranded bundle

Polyester foil over stranded bundle

Shielding 2

Polyester foil, Copper bare

Polyester foil, aluminum-lined

Total Shielding

Copper shifting, tinned

Copper braid, tinned

Outer Jacket Material

PUR

PVC

Outer Diameter

8.0 mm ± 0.3 mm

8.0 mm ± 0.3 mm

Outer Jacket Color

Violet

Green

Dati elettrici:

CharacteristicImpedance@3-20Hz

150 Ω ± 10 Ω

Conductor Resistance

66.5 Ohm/km max.

Insulation Resistance

1.00 GOhm x km min.

Mutual Capacitance@1KHz

30.0 nF/km nom.

Working Voltage

 Max: 250 V

Test Voltage

1.5 KV

Attenuation:

9.6

kHz

3.0

dB/km

38.4

kHz

5.0

dB/km

4.0

MHz

25.0

dB/km

16.0

MHz

51.0

dB/km

Dati tecnici:

Weight

approximately 91.0 kg/km

approximately 64.0 kg/km

Min. Bending Radius (Laying)

12.5 x OD mm

5 x OD mm

Operating Temp.Range, min.

- 5 °C

-40 °C

Operating Temp.Range, max.

+60 °C