Home
Chi siamo
Prodotti
Scaricare
Biblioteca tecnica
Contatto
Richiesta
Mappa del sito 
Collegamenti
 

Allarme & Cavo Audio & Elettronico

Cavo di Equivalente di Belden

Cavo coassiale

Cavo di Controllo

Cavo Fibra Ottica

Cavo Flessibile

Cavo strumentazione

Cavi LAN
Cavo Energia
CavoFerroviario

Robotic

Cavo per Materiale Rotabile
Cavo di gomma
Cavo di Sicurezza

Cavo Telefonico

Aeroporto Cavo

Bus Cavo

Serracavi

Data Cable

Calore di rilevamento Cavo
Cavo ad alta temperatura
Cavo autostrada
Marine, petrolio, gas e petrolchimico Cavo
Cavo Speciali
Cavo a spirale
Termocoppia Cavo
     
  indoor tight buffer fiber optic cable  
Indoor Used Tight Buffered Fiber
Optical Cable
outdoor multi loose tube fiber optic cable
Outdoor Used Multi Loose Tube
Fiber Optical Cable
 
  Termocoppia Cavi   

Thermocouple Cable EX, JX, KX, TX 600V, 90°C Wet or Dry

Applicazione:

For use as a 600 Volt, multi-pair thermocouple instrumentation cable where flame-retardance, and moisture/chemical resistance is critical. Cable can be installed in free air, in raceways, or direct burial. The cable is also approved for wet or dry locations as well as Class 1 Division II industrial hazardous locations per NEC 501-4(b) for (UL) Type Tray Cables (TC).
Temperature rating of 90°C wet or dry. Insulation provides excellent electrical, thermal, and physical properties, excellent flame resistance and resistant to crush, compression, cuts and heat deformation. Also conductor insulation provides good low temperature (-40°C) cold bend characteristics. Approved for direct burial.

Costruzione:

  • Conductor is thermocouple alloy per ANSI MC96.1 - 1982.
  • Extruded flame-retardant ethylene propylene rubber (EPR) insulation.
  • Conductors twisted together with a drain wire and aluminum mylar shield. Shielded pairs cabled together with fillers as needed to form a round core. An overall aluminum mylar shield and drain wire is applied over the core.
  • Pairs are color coded per thermocouple type with pair number printed on the negative (red) conductor. See chart below for specific color codes.
  • Black, flame-retardant, sunlight resistant, Chlorinated Polyethylene (CPE) jacket. Available with color coded jacket.
  • Available with class B stranding per ASTM B174.

Standards:

  • Insulated Conductor - VW-1.
  • UL Type TC, 90°C Wet or Dry, 600V
  • ICEA S-82-552, 90°C Wet or Dry, 600V.
  • Passes UL 1277 Flame Test (70,000 BTU/hr).
  • Passes UL 1202 Flame Test (70,000 BTU/hr).
  • Passes IEEE 383 Flame Test (70,000 BTU/hr).
  • Passes ICEA T-29-520 Flame Test (210,000 BTU/hr).

EX - Color Code

  • Chromel (Positive) - PURPLE
  • Constantan (Negative) - RED

JX - Color Code

  • Iron (Positive) - WHITE
  • Constantan (Negative) - RED

TX - Color Code

  • Copper (Positive) - BLUE
  • Constantan (Negative) - RED

KX - Color Code

  • Chromel (Positive) - YELLOW
  • Alumel (Negative) - RED
Item # Number of
Shielded Pairs
Insulation Thickness
(mils)
Jacket Thickness
(mls)
Overall
Diameter
(inches)
Weight LBS/MFT
ITC-20-1 1 0.025 0.045 0.270 35
ITC-20-2 2 0.025 0.045 0.035 70
ITC-20-3 3 0.025 0.045 0.450 85
ITC-20-4 4 0.025 0.045 0.500 105
ITC-20-6 6 0.025 0.045 0.600 160
ITC-20-8 8 0.025 0.045 0.670 210
ITC-20-10 10 0.025 0.045 0.735 240
ITC-20-12 12 0.025 0.045 0.790 280
ITC-20-16 16 0.025 0.045 0.890 360
ITC-20-24 24 0.025 0.045 1.060 500
ITC-18-1 1 0.025 0.045 0.300 50
ITC-18-2 2 0.025 0.045 0.480 90
ITC-18-3 3 0.025 0.045 0.510 115
ITC-18-4 4 0.025 0.045 0.595 165
ITC-18-6 6 0.025 0.045 0.670 220
ITC-18-8 8 0.025 0.045 0.750 280
ITC-18-10 10 0.025 0.045 0.820 340
ITC-18-12 12 0.025 0.045 0.930 430
ITC-18-16 16 0.025 0.045 1.045 540
ITC-18-24 24 0.025 0.045 1.235 760
ITC-16-1 1 0.025 0.045 0.325 60
ITC-16-2 2 0.025 0.045 0.570 130
ITC-16-3 3 0.025 0.045 0.600 160
ITC-16-4 4 0.025 0.045 0.660 200
ITC-16-6 6 0.025 0.045 0.740 270
ITC-16-8 8 0.025 0.045 0.880 380
ITC-16-10 10 0.025 0.045 0.970 460
ITC-16-12 12 0.025 0.045 1.035 530
ITC-16-16 16 0.025 0.045 1.165 570
ITC-16-24 24 0.025 0.045 1.400 960