Home
Over ons
Produkten
Downloaden
Technische Lib
Contact
Navraag
Sitemap
Links
 

Alarm & Audio & Elektronische Kabel

Belden gelijkwaardige kabels

Coax Kabels

Control Kabels

Fiber Optic Kabels

Flexibele Kabels

Instrumentatie Kabel

Lan kabels
Energie Kabel
Spoorweg Kabel

Robotica

Rollend materieel kabels
Rubber & Crane kabels
Beveiliging kabels

Telefoonkabels

Luchthaven Kabels

Bus kabels

Kabel Klieren

Data Kabels

Hitte detectie kabels
Hoge temperatuur kabels
Kabels snelweg
Marine, olie-, gas-en petrochemische Kabels
Speciaal Kabels
Spiraal Kabels
Thermokoppel Kabels
     
  Indoor tight buffer fiber optic cable  
Indoor Used Tight Buffered Fiber
Optical Cable
outdoor multi loose tube fiber optic cable
Outdoor Used Multi Loose Tube
Fiber Optical Cable
 
  Thermokoppel Kabels 

Thermocouple Cable EX, JX, KX, TX 600V, 90°C Wet or Dry

Aanvraag:

For use as a 600 Volt, multi-pair thermocouple instrumentation cable where flame-retardance, and moisture/chemical resistance is critical. Cable can be installed in free air, in raceways, or direct burial. The cable is also approved for wet or dry locations as well as Class 1 Division II industrial hazardous locations per NEC 501-4(b) for (UL) Type Tray Cables (TC).
Temperature rating of 90°C wet or dry. Insulation provides excellent electrical, thermal, and physical properties, excellent flame resistance and resistant to crush, compression, cuts and heat deformation. Also conductor insulation provides good low temperature (-40°C) cold bend characteristics. Approved for direct burial.

Bouw:

  • Conductor is thermocouple alloy per ANSI MC96.1 - 1982.
  • Extruded flame-retardant ethylene propylene rubber (EPR) insulation.
  • Conductors twisted together with a drain wire and aluminum mylar shield. Shielded pairs cabled together with fillers as needed to form a round core. An overall aluminum mylar shield and drain wire is applied over the core.
  • Pairs are color coded per thermocouple type with pair number printed on the negative (red) conductor. See chart below for specific color codes.
  • Black, flame-retardant, sunlight resistant, Chlorinated Polyethylene (CPE) jacket. Available with color coded jacket.
  • Available with class B stranding per ASTM B174.

Normen:

  • Insulated Conductor - VW-1.
  • UL Type TC, 90°C Wet or Dry, 600V
  • ICEA S-82-552, 90°C Wet or Dry, 600V.
  • Passes UL 1277 Flame Test (70,000 BTU/hr).
  • Passes UL 1202 Flame Test (70,000 BTU/hr).
  • Passes IEEE 383 Flame Test (70,000 BTU/hr).
  • Passes ICEA T-29-520 Flame Test (210,000 BTU/hr).

EX - Kleur code

  • Chromel (Positive) - PURPLE
  • Constantan (Negative) - RED

JX - Kleur code

  • Iron (Positive) - WHITE
  • Constantan (Negative) - RED

TX - Kleur code

  • Copper (Positive) - BLUE
  • Constantan (Negative) - RED

KX - Kleur code

  • Chromel (Positive) - YELLOW
  • Alumel (Negative) - RED
Item # Aantal Shielded Pairs Isolatiedikte
(mils)
Jacket Dikte
(mls)
Overall
Diameter
(inches)
Gewicht
LBS/MFT
ITC-20-1 1 0.025 0.045 0.270 35
ITC-20-2 2 0.025 0.045 0.035 70
ITC-20-3 3 0.025 0.045 0.450 85
ITC-20-4 4 0.025 0.045 0.500 105
ITC-20-6 6 0.025 0.045 0.600 160
ITC-20-8 8 0.025 0.045 0.670 210
ITC-20-10 10 0.025 0.045 0.735 240
ITC-20-12 12 0.025 0.045 0.790 280
ITC-20-16 16 0.025 0.045 0.890 360
ITC-20-24 24 0.025 0.045 1.060 500
ITC-18-1 1 0.025 0.045 0.300 50
ITC-18-2 2 0.025 0.045 0.480 90
ITC-18-3 3 0.025 0.045 0.510 115
ITC-18-4 4 0.025 0.045 0.595 165
ITC-18-6 6 0.025 0.045 0.670 220
ITC-18-8 8 0.025 0.045 0.750 280
ITC-18-10 10 0.025 0.045 0.820 340
ITC-18-12 12 0.025 0.045 0.930 430
ITC-18-16 16 0.025 0.045 1.045 540
ITC-18-24 24 0.025 0.045 1.235 760
ITC-16-1 1 0.025 0.045 0.325 60
ITC-16-2 2 0.025 0.045 0.570 130
ITC-16-3 3 0.025 0.045 0.600 160
ITC-16-4 4 0.025 0.045 0.660 200
ITC-16-6 6 0.025 0.045 0.740 270
ITC-16-8 8 0.025 0.045 0.880 380
ITC-16-10 10 0.025 0.045 0.970 460
ITC-16-12 12 0.025 0.045 1.035 530
ITC-16-16 16 0.025 0.045 1.165 570
ITC-16-24 24 0.025 0.045 1.400 960