|
|
Marine Cable |
Marine Cables to NEK606
RG6 Armoured Coaxial Cable
Applications
These 75Ω coaxial cables are suitable for installation on board of ships and other indoor marine environments.
Standards
- IEC 60092-350
- IEC 60332-3-22
- IEC 60754-1,2
- IEC 61034-1,2
- NEK 606:2004
Construction
Conductors |
18AWG solid bare copper. |
Insulation |
Foam PE. |
Shielding1 |
Al/Polyester/Al tape. |
Shielding2 |
Tinned copper braid. |
Bedding |
Low smoke and halogen-free polyolefin, coloured black. |
Armour |
Copper wire braid. |
Outer Sheath |
Low smoke and halogen-free polyolefin. |
Electrical Characteristics
AWG |
|
18 |
Nominal Conductor Diameter |
mm |
1.0 |
Impedance |
Ω |
75+/-5 |
Nominal Attenuation@100MHz |
dB/100m |
6.9 |
Nominal Attenuation@200MHz |
dB/100m |
9.0 |
Nominal Attenuation@300MHz |
dB/100m |
11.8 |
Nominal Attenuation@400MHz |
dB/100m |
13.1 |
Nominal Attenuation@500MHz |
dB/100m |
15.4 |
Nominal Attenuation@900MHz |
dB/100m |
21.5 |
Nominal Attenuation@1700MHz |
dB/100m |
29.4 |
Capacitance |
pF/m |
53.5 |
Velocity of Propagation |
% |
83 |
Conductor DCR |
Ω/km |
21.4 |
Shield DCR |
Ω/km |
7.5 |
Inductance |
μH/m |
0.32 |
Time Delay |
ns/m |
4 |
Mechanical and Thermal Properties
Bending Radius |
15×OD |
Temperature Range |
-30℃ ~ +75℃ |
Dimensions and Weight
Nominal Inner Conductor Diameter (mm) |
Nominal Insulation Thickness (mm) |
Nominal Sheath Thickness (mm) |
Nominal Overall Diameter (mm) |
Nominal Weight (kg/km) |
1.0 |
1.8 |
1.2 |
11.2 |
208 |