Mining Cable
NTMTWOEU 0.6/1kV Mine Hoist Cables
Applications
These cables are used as suspended cable for intrinsically safe control of user-operated mine hoists (lifts) with telephonic connection in underground mines.
Standards
VDE 0250 Part 813
Construction
Conductors: Flexible stranded tinned copper conductor, class 5 according to DIN VDE 0295.
Insulation: EPR type 3GI3.
Support Element: Central steel support element.
Anti-torsion Braid:Textile braid.
Outer Sheath: PCP rubber type 5GM5.
Dimensions and Weight
Number of Cores×Nominal Cross Section |
Minimum Overall Diameter |
Maximum Overall Diameter |
Nominal Weight |
No.×mm² |
mm |
mm |
kg/km |
8x2.5ST+2x1FM(C) |
21.7 |
23.7 |
800 |
8x2.5ST+10x (2x1FM)C |
34.0 |
37.5 |
1450 |
14x2.5ST+6x1FM(C) |
27.0 |
31.0 |
1200 |
18x2.5ST+6x1FM(C) |
38.0 |
42.0 |
1800 |
19x1.5(C)ST+6x (2x1FM)C |
35.1 |
38.1 |
2145 |