IEC60092 STANDARD Offshore & Marine Cables |
IEC60092 STANDARD Offshore & Marine Cables
MRE-2XCH 150/250V XLPE Insulated, LSOH (SHF1) Sheathed, Armoured Flame Retardant Instrumentation & Control Cables (Multicore)
Applications
These armoured cables are used on board of ships in all locations for fixed installations complying with IEC standards 60092-352. These cables are flame retardant, low smoke & halogen free, suitable for installations on passenger ships, as on other commercial vessels.
Standards
- IEC 60092-350/351/376/359
- IEC 60332-1
- IEC 60332-3-22
- IEC 60754-1/2
- IEC 61034
Construction
Conductors |
Class 2 stranded copper conductor. |
Insulation |
XLPE. |
Inner Covering |
Lapping.
|
Armour |
Copper wire braid. |
Outer Sheath |
LSOH (SHF1).SHF2 can be offered upon request. |
Core Identification
White with printed number.
Mechanical and Thermal Properties
Bending Radius for Fixed Installations |
6×OD |
Temperature Range |
-30℃ ~ +80℃ |
Dimensions and Weight
Part No. |
Construction No. of cores×Cross section |
Nominal Insulation Thickness |
Nominal Sheath Thickness |
Nominal Overall Diameter |
Nominal Weight |
|
mm²) |
mm |
mm |
mm |
kg/km |
MRE-2XCH-2C0.75 |
2×0.75 |
0.5 |
1.2 |
7.2 |
80 |
MRE-2XCH-3C0.75 |
3×0.75 |
0.5 |
1.2 |
7.5 |
90 |
MRE-2XCH-5C0.75 |
5×0.75 |
0.5 |
1.4 |
8.9 |
130 |
MRE-2XCH-7C0.75 |
7×0.75 |
0.5 |
1.6 |
9.8 |
150 |
MRE-2XCH-12C0.75 |
12×0.75 |
0.5 |
1.7 |
12.4 |
230 |
MRE-2XCH-19C0.75 |
19×0.75 |
0.5 |
1.9 |
14.6 |
320 |
MRE-2XCH-27C0.75 |
27×0.75 |
0.5 |
2.1 |
17.3 |
460 |
MRE-2XCH-37C0.75 |
37×0.75 |
0.5 |
2.2 |
19.3 |
590 |
MRE-2XCH-2C1.0 |
2×1.0 |
0.5 |
1.4 |
7.9 |
90 |
MRE-2XCH-3C1.0 |
3×1.0 |
0.5 |
1.4 |
8.3 |
100 |
MRE-2XCH-5C1.0 |
5×1.0 |
0.5 |
1.5 |
9.7 |
150 |
MRE-2XCH-7C1.0 |
7×1.0 |
0.5 |
1.6 |
10.4 |
180 |
MRE-2XCH-12C1.0 |
12×1.0 |
0.5 |
1.8 |
13.2 |
270 |
MRE-2XCH-19C1.0 |
19×1.0 |
0.5 |
2.1 |
15.9 |
420 |
MRE-2XCH-27C1.0 |
27×1.0 |
0.5 |
2.2 |
18.4 |
560 |
MRE-2XCH-37C1.0 |
37×1.0 |
0.5 |
2.4 |
20.7 |
710 |