IEC60092 STANDARD Offshore & Marine Cables |
IEC60092 STANDARD Offshore & Marine Cables
MRE-M2XH 150/250V Mica Tape + XLPE Insulated, LSOH (SHF1) Sheathed Fire Resistant Instrumentation & Control Cables (Multicore)
Applications
These cables are used on board of ships in all locations for fixed installations not subject to mechanical risk complying with IEC standards 60092-352 in safety circuit, where fire resistance is required. These cables are fire resistant, flame retardant, low smoke & halogen free, suitable for installations on passenger ships, as on other commercial vessels.
Standards
- IEC 60092-350/351/376/359
- IEC 60331-21
- IEC 60332-1
- IEC 60332-3-22
- IEC 60754-1/2
- IEC 61034
Construction
Conductors |
Class 2 stranded copper conductor. |
Insulation |
Mica tape + XLPE. |
Outer Sheath |
LSOH (SHF1).SHF2 can be offered upon request. |
Core Identification
White with printed number.
Mechanical and Thermal Properties
Bending Radius for Fixed Installations |
4×OD |
Temperature Range |
-30℃ ~ +80℃ |
Dimensions and Weight
Part No. |
Construction No. of cores×Cross section |
Nominal Insulation Thickness |
Nominal Sheath Thickness |
Nominal Overall Diameter |
Nominal Weight |
|
mm² |
mm |
mm |
mm |
kg/km |
MRE-M2XH-2C0.75 |
2×0.75 |
0.5 |
1.1 |
6.3 |
63 |
MRE-M2XH-4C0.75 |
4×0.75 |
0.5 |
1.2 |
6.7 |
84 |