Flame Retardant Overall Screened, Armoured Instrumentation Cables (Multipair)
RE-2X(St)YSWAY
APPLICATION
The armoured PVC versions (Part 1 Type 2) are generally used when the risk of mechanical damage
is increased. The galvanized steel wire armour provides excellent protection. Generally used within
industrial process manufacturing plants for communication, data and voice transmission signals and
services.
STANDARDS
Basic design adapted to BS 5308 Part1 Type 2
FIRE PERFORMANCE
Flame Retardance (Single Vertical
Wire Test)** |
EN 60332-1-2; IEC 60332-1-2; BS EN 60332-1-2; VDE
0482-332-1 ; NBN C 30-004 (cat. F1); NF C32-070-2.1(C2); CEI 20-35/1-2; EN 50265-2-1*; DIN VDE 0482-265-2-1* |
Reduced Fire Propagation
(Vertically-mounted bundled wires
& cable test)** |
EN 60332-3-24 (cat. C); IEC 60332-3-24; BS EN 60332-3-24; VDE 0482-332-3; NBN C 30-004 (cat. F2); NF C32-070-2.2(C1); CEI 20-22/3-4; EN 50266-2-4*; DIN VDE 0482-266-2-4 |
Note: Asterisk ** denotes that the standard compliance is optional, depending on the oxygen index of the PVC
compound and the cable design.
VOLTAGE RATING
300/500V
CABLE CONSTRUCTION
Conductor: Annealed or tinned copper, sizes: 0.5mm² and 0.75mm² mulitistranded(Class 5), 0.5
mm², 1.0 mm² solid(Class 1), 1.5mm² or 2.5mm², multistranded(Class 2) to BS6360
Insulation: XLPE (Cross Linked Polyethylene), or PE (optional)
Pairs: Two insulated conductors uniformly twisted together with a lay not exceeding 100mmBinder tape: PETP transparent tape
Overall Screen: Aluminium/polyester tape is applied over the laid up pairs metallic side down in
contact with tinned copper drain wire, 0.5mm²
Inner Sheath: PVC compound
Amouring: Galvanized steel wire armour
Outer Sheath: Thermoplastic PVC compound. UV resistance, hydrocarbon resistance, oil resistance,
anti rodent and anti termite properties can be offered as option. Compliance to fire performance
standard (IEC 60332-1, IEC 60332-3, UL 1581, UL 1666 etc) depends on the oxygen index of the
PVC compound and the overall cable design. LSPVC can also be provided upon request.
COLOUR CODE
Insulation Colour: See technical information
Outer sheath: Black or blue
Physical AND THERMAL PROPERTIES
Maximum Operating temperature: -20˚C - + 90˚C( fixed installation)
0˚C -+50˚C(during operation)
Minimum bending radius: 6 x Overall Diameter
Electrical Properties
Conductor Area Size |
mm2 |
0.5 |
0.5 |
0.75 |
1.0 |
1.5 |
Conductor Stranding |
No. x
mm |
1 x 0.8 |
16 x 0.2 |
24 x 0.2 |
1 x 1.13 |
7 x 0.53 |
Conductor resistance max |
ohm/km |
36.8 |
39.7 |
26.5 |
18.2 |
12.3 |
Insulation resistance min |
Gohm/
km |
5 |
5 |
5 |
5 |
5 |
Capacitance unbalance at 1
kHz(pair to pair screen) |
pF/250m |
250 |
Max. Mutual Capacitance @ 1 kHz forNon OS or OS cables (except one-pair and two-pairs) |
pF/m |
115 |
115 |
115 |
115 |
120 |
Max. Mutual Capacitance @
1 kHz IS/OS cables (include 1 pair and 2 pair) |
pF/m |
75 |
75 |
75 |
75 |
85 |
Max. L/R Ratio for adjacent
cores(Inductance/Resistance) |
μH/ohm |
25 |
25 |
25 |
25 |
40 |
Test voltage |
Core to core |
V |
1000 |
1000 |
1000 |
1000 |
1000 |
Core to screen |
V |
1000 |
1000 |
1000 |
1000 |
1000 |
Rated voltage max |
V |
300/500 |
300/500 |
300/500 |
300/500 |
300/500 |
CONSTRUCTION PARAMETERS
Number of Pairs |
No./ Nominal Diameter of Strands |
Nominal
Conductor Cross- Section Area |
Nominal Insulation Thickness |
Nominal Sheath Thickness |
Nominal Overall Diameter |
Approx. Weight |
Nominal Thick- ness of
Sheath |
Nominal Dia. of Cable |
Approx. Weight |
no./mm |
mm2 |
mm |
mm |
mm |
kg/km |
mm |
mm |
kg/km |
1 |
1/0.80 |
0.5 |
0.5 |
0.8 |
5.5 |
0.9 |
1.3 |
9.9 |
200 |
2 |
1/0.80 |
0.5 |
0.5 |
0.8 |
6.8 |
0.9 |
1.3 |
11.2 |
260 |
5 |
1/0.80 |
0.5 |
0.5 |
1.1 |
10.9 |
0.9 |
1.4 |
15.5 |
460 |
10 |
1/0.80 |
0.5 |
0.5 |
1.2 |
14.4 |
1.25 |
1.6 |
20.1 |
790 |
15 |
1/0.80 |
0.5 |
0.5 |
1.2 |
16.5 |
1.25 |
1.6 |
22.2 |
1100 |
20 |
1/0.80 |
0.5 |
0.5 |
1.3 |
18.8 |
1.6 |
1.7 |
25.4 |
1280 |
30 |
1/0.80 |
0.5 |
0.5 |
1.3 |
22.3 |
1.6 |
1.8 |
29.1 |
1520 |
50 |
1/0.80 |
0.5 |
0.5 |
1.5 |
28.5 |
1.6 |
2 |
35.7 |
2100 |
1 |
16/0.2 |
0.5 |
0.6 |
0.8 |
6.2 |
0.9 |
1.3 |
10.6 |
250 |
2 |
16/0.2 |
0.5 |
0.6 |
0.8 |
7.6 |
0.9 |
1.3 |
12 |
300 |
5 |
16/0.2 |
0.5 |
0.6 |
1.1 |
12.4 |
0.9 |
1.5 |
17.2 |
560 |
10 |
16/0.2 |
0.5 |
0.6 |
1.2 |
16.5 |
1.25 |
1.6 |
22.2 |
970 |
15 |
16/0.2 |
0.5 |
0.6 |
1.3 |
19.2 |
1.6 |
1.7 |
25.8 |
1240 |
20 |
16/0.2 |
0.5 |
0.6 |
1.3 |
21.7 |
1.6 |
1.8 |
28.5 |
1640 |
30 |
16/0.2 |
0.5 |
0.6 |
1.5 |
26.4 |
1.6 |
1.9 |
33.4 |
1770 |
50 |
16/0.2 |
0.5 |
0.6 |
1.7 |
33.4 |
2 |
2.1 |
41.6 |
2770 |
1 |
24/0.2 |
0.75 |
0.6 |
0.8 |
6.7 |
0.9 |
1.4 |
10.9 |
280 |
2 |
24/0.2 |
0.75 |
0.6 |
0.9 |
8.4 |
0.9 |
1.4 |
12.8 |
330 |
5 |
24/0.2 |
0.75 |
0.6 |
1.2 |
13.8 |
1.25 |
1.6 |
19.3 |
750 |
10 |
24/0.2 |
0.75 |
0.6 |
1.3 |
18.4 |
1.6 |
1.8 |
24.3 |
1260 |
15 |
24/0.2 |
0.75 |
0.6 |
1.3 |
21.1 |
1.6 |
1.9 |
27 |
1480 |
20 |
24/0.2 |
0.75 |
0.6 |
1.5 |
24.4 |
1.6 |
2 |
31.4 |
1890 |
30 |
24/0.2 |
0.75 |
0.6 |
1.7 |
29.5 |
2 |
2.1 |
37 |
2440 |
50 |
24/0.2 |
0.75 |
0.6 |
2 |
37.6 |
2.5 |
2.4 |
47.3 |
3210 |
1 |
1/1.13 |
1 |
0.6 |
0.8 |
6.6 |
0.9 |
1.3 |
11 |
290 |
2 |
1/1.13 |
1 |
0.6 |
0.8 |
8 |
0.9 |
1.4 |
12.6 |
345 |
5 |
1/1.13 |
1 |
0.6 |
1.2 |
13.5 |
1.25 |
1.5 |
19 |
790 |
10 |
1/1.13 |
1 |
0.6 |
1.2 |
17.7 |
1.25 |
1.7 |
23.6 |
1310 |
15 |
1/1.13 |
1 |
0.6 |
1.3 |
20.6 |
1.6 |
1.8 |
27.4 |
1740 |
20 |
1/1.13 |
1 |
0.6 |
1.5 |
23.8 |
1.6 |
1.8 |
30.6 |
2040 |
30 |
1/1.13 |
1 |
0.6 |
1.5 |
28.4 |
1.6 |
2 |
35.6 |
2180 |
50 |
1/1.13 |
1 |
0.6 |
2 |
36.6 |
2 |
2.2 |
45 |
3500 |
1 |
7/0.53 |
1.5 |
0.6 |
0.8 |
7.5 |
0.9 |
1.4 |
11.9 |
320 |
2 |
7/0.53 |
1.5 |
0.6 |
0.9 |
9.3 |
0.9 |
1.5 |
14.1 |
420 |
5 |
7/0.53 |
1.5 |
0.6 |
1.2 |
15.6 |
1.25 |
1.6 |
21.6 |
940 |
10 |
7/0.53 |
1.5 |
0.6 |
1.3 |
20.9 |
1.6 |
1.8 |
27.4 |
1500 |
15 |
7/0.53 |
1.5 |
0.6 |
1.5 |
24.6 |
1.6 |
1.9 |
31.2 |
1970 |
20 |
7/0.53 |
1.5 |
0.6 |
1.5 |
27.8 |
1.6 |
2 |
35.8 |
2400 |
30 |
7/0.53 |
1.5 |
0.6 |
1.7 |
33.7 |
2 |
2.2 |
42.3 |
3170 |
50 |
7/0.53 |
1.5 |
0.6 |
2 |
43 |
2.5 |
2.5 |
53.2 |
5020 |
|