Robotics |
|||||||||||||
Robotics
Extra Flex R7 XLPE-TPPE
Code |
Formation |
Ext.Diam mm |
CU-weight kg/km |
R7B9RDX |
3x(2x0.14) + 1x(3x0.14) |
7.1 |
27 |
APPLICATION :
Special cable "resolver" for robots, Dynamic applications.
TECHNICAL CHARACTERISTICS :
Service Voltage :
250V
Test Voltage :
1500V
Insulation Resistance :
>/= 3000 Mohm x km (at 20oC)
Capacitance :
Abt. 85 nF/km at 20oC
Temperature :
Service from 0oC to +80oC, storage from -40oC to + 80oC
Conductor Stranding :
Extra-flexible class 6 acc. Standards VDE 0295 - IEC 228 - CEI 20-29 tinned copper
Primary Insulation :
XLPE cross-linked polyethylene
Conductors Identification :
3 pairs: (NAT-RD) - (NAT-BL) - (NAT-BLK) 1 tern: BR - BLK - BLUE
Shield :
3 pairs 2 x 0.14: tinned copper spiral cov. abt. 95%
Taping :
Special tape
Jacket :
TPPE thermoplastic polyester polyether elastomer black colour RAL 9005
Min. Bending Radius :
100mm
Translation Speed :
180m/min.
Max. Acceleration :
5m/s2
Reference Standards :
VDE 0472-804 B - IEC 332.1 - CEI 20-35 for flame resistance VDE 0472-815 halogen-free version.