Rolling Stock Cables

DATABUS RS 485 CABLE

Databus RS 485 Cable

Voltage

Cable Type

Construction

Number

of Cores

Cross Sectional
Areas/

Stranding Class

Design Standard

Fire Standard

300/500V

Multipair,

with jacket screened

CU/XL FOAM PE/ALTO/CUTO/EM 104 EVA

1-4 Pr

0.22-1mm2

Class 5 stranding

EN 50264, DIN 5510

IEC 332-3C IEC 754 IEC1034

300/500V

Multipair,

with jacket screened

CU/XL FOAM PE/CUTO/EM 104 EVA

1-4 Pr

0.22-1mm2

Class 5 stranding

EN 50264, DIN 5510

BS 6853 NF F 16-101 FO

300/500V Multipair Databus RS 485 Double screened Cable

Cross-sectional Area

0.22mm2-1mm2

Voltage rating

300/500V

Conductor

Flexible Stranded Tinned Copper

Number of pair

1-4

Conductor class

IEC 60228 Class 5

Insulation

Cross linked Foam PE

Screen

Individual Aluminium Tape+Overall Copper Wire Braid

Jacket

Cross linked EVA rubber type EM 104 or equivalent, in accordance with EN 50264-1

Fire Standard

IEC 332-3C IEC 754 IEC1034

Electrical Characteristic

Impedance

120 ohm ±15%

Capacitance

41nF/Km@1KHz

Insulation Resistance

5000 M ohm


No.of Pairs

Cross Sectional Area

(mm2)

Number and Nominal Diameter of Strands

(mm)

Voltage Rating

(V)

Nominal Overall
Diameter

(mm)

Nominal Weight

(kg/km)

1

0.22

7/0.2

300/500

4.5

58

2

0.22

7/0.2

300/500

6.2

79

4

0.22

7/0.2

300/500

6.5

118

1

0.5

16/0.2

300/500

6.6

79

2

0.5

16/0.2

300/500

9.0

105

4

0.5

16/0.2

300/500

9.8

145

1

0.75

24/0.2

300/500

9.5

115

2

0.75

24/0.2

300/500

10.3

135

4

0.75

24/0.2

300/500

11.6

182

1

1

30/0.2

300/500

11.5

125

2

1

30/0.2

300/500

12.5

150

4

1

30/0.2

300/500

13.5

180

300/500V Multipair Databus RS 485 Single screened Cable

Cross- sectional Area

0.22mm2-1mm2

Voltage rating

300/500V

Conductor

Flexible Stranded Tinned Copper

Number of pair

1-4

Conductor class

IEC 60228 Class 5

Insulation

Cross linked Foam PE

Screen

Copper Wire Braid

Jacket

Cross linked EVA rubber type EM 104 or equivalent, in accordance with EN 50264-1

Fire Standard

BS 6853 Category la,lb and 11 and NF F 16-101 FO

Electrical Characteristic

Impedance

120 ohm ±15%

Capacitance

41nF/Km@1KHz

Insulation Resistance

5000 M ohm


No. of Pairs

Cross Sectional Area

(mm2)

Number and Nominal Diameter of Strands

(mm)

Voltage Rating

(V)

Nominal Overall
Diameter

(mm)

Nominal Weight

(kg/km)

1

0.22

7/0.2

300/500

4.2

55

2

0.22

7/0.2

300/500

5.9

75

4

0.22

7/0.2

300/500

6.2

115

1

0.5

16/0.2

300/500

6.3

75

2

0.5

16/0.2

300/500

8.5

100

4

0.5

16/0.2

300/500

9.4

140

1

0.75

24/0.2

300/500

9.0

110

2

0.75

24/0.2

300/500

9.7

130

4

0.75

24/0.2

300/500

11.1

178

1

1

30/0.2

300/500

11.0

120

2

1

30/0.2

300/500

12.0

145

4

1

30/0.2

300/500

13.0

175

300/500V Multipair Databus RS 485 Single screened Cable

Cross- sectional Area

0.22mm2-1mm2

Voltage rating

300/500V

Conductor

Flexible Stranded Tinned Copper

Number of pair

1-4

Conductor class

IEC 60228 Class 5

Insulation

Cross linked Foam PE

Screen

Copper Wire Braid

Jacket

Cross linked EVA rubber type EM 104 or equivalent, in accordance with EN 50264-1

Fire Standard

BS 6853 Category la,lb and 11 and NF F 16-101 FO

Electrical Characteristic

Impedance

120 ohm ±15%

Capacitance

41nF/Km@1KHz

Insulation Resistance

5000 M ohm


No. of Pairs

Cross Sectional Area

(mm2)

Number and Nominal Diameter of Strands

(mm)

Voltage Rating

(V)

Nominal Overall
Diameter

(mm)

Nominal Weight

(kg/km)

1

0.22

7/0.2

300/500

4.2

55

2

0.22

7/0.2

300/500

5.9

75

4

0.22

7/0.2

300/500

6.2

115

1

0.5

16/0.2

300/500

6.3

75

2

0.5

16/0.2

300/500

8.5

100

4

0.5

16/0.2

300/500

9.4

140

1

0.75

24/0.2

300/500

9.0

110

2

0.75

24/0.2

300/500

9.7

130

4

0.75

24/0.2

300/500

11.1

178

1

1

30/0.2

300/500

11.0

120

2

1

30/0.2

300/500

12.0

145

4

1

30/0.2

300/500

13.0

175