DPNP, TPNP, FPNP
STANDARDS
JISC 3410-1999
IEC 60332-1
CABLE CONSTRUCTION
Conductor |
D(T,F) |
Tinned annealed stranded copper, class 5 according to IEC 60228 |
Insulation |
P |
85°C EPR as per JIS C 3410 |
Cabling |
|
Insulated conductors shall be cabled.
Flame retardant & non-hygroscopic fillers may be used |
Sheath |
NP |
PCP as per JIS C 3410 |
Core identification |
|
2C Black, White
3C Black, White, Red
4C Black, White, Red, Green |
Outer sheath color |
|
Black |
Cable Parameter
No. of
Cores |
Conductor |
Thick. of insulation |
Thick. of
Sheath |
Nom. overall dia. |
Tolerance |
Cable
Weight |
Size |
Construction |
O.D |
mm² |
No./mm |
mm |
mm |
mm |
mm |
mm |
kg/km |
2 |
0.75 |
24/0.20 |
1.13 |
1 |
1.4 |
9.7 |
0.4 |
130 |
2 |
1 |
32/0.20 |
1.27 |
1 |
1.4 |
9.9 |
0.4 |
135 |
2 |
1.5 |
30/0.25 |
1.58 |
1 |
1.5 |
10.8 |
0.4 |
165 |
2 |
2.5 |
49/0.25 |
2.02 |
1 |
1.6 |
11.8 |
0.5 |
205 |
2 |
4 |
55/0.30 |
2.57 |
1 |
1.7 |
13.1 |
0.5 |
265 |
2 |
6 |
82/0.30 |
3.14 |
1 |
1.8 |
14.5 |
0.6 |
340 |
3 |
0.75 |
24/0.20 |
1.13 |
1 |
1.4 |
10.2 |
0.4 |
145 |
3 |
1 |
32/0.20 |
1.27 |
1 |
1.5 |
10.7 |
0.4 |
160 |
3 |
1.5 |
30/0.25 |
1.58 |
1 |
1.5 |
11.4 |
0.5 |
190 |
3 |
2.5 |
49/0.25 |
2.02 |
1 |
1.6 |
12.5 |
0.5 |
240 |
3 |
4 |
55/0.30 |
2.57 |
1 |
1.8 |
14.1 |
0.6 |
325 |
3 |
6 |
82/0.30 |
3.14 |
1 |
1.9 |
15.6 |
0.6 |
420 |
4 |
0.75 |
24/0.20 |
1.13 |
1 |
1.5 |
11.3 |
0.5 |
175 |
4 |
1 |
32/0.20 |
1.27 |
1 |
1.6 |
11.8 |
0.5 |
200 |
4 |
1.5 |
30/0.25 |
1.58 |
1 |
1.6 |
12.2 |
0.5 |
225 |
4 |
2.5 |
49/0.25 |
2.02 |
1 |
1.8 |
14.1 |
0.6 |
310 |
4 |
4 |
55/0.30 |
2.57 |
1 |
1.9 |
15.6 |
0.6 |
405 |
4 |
6 |
82/0.30 |
3.14 |
1 |
2 |
17.2 |
0.7 |
525 |
|