Germany Standard Automotive Cable

FLR13Y-B

Applications

This TPE insulated low-tension automotive cable is used in motorcycles and other motor vehicles for starting , charging, lighting, signal and instrument panel circuits.

Construction

FLR13Y
Conductor Cu-ETP1 bare according to DIN EN13602
Insulation Thermoplastic elastomeric on polyester basis (TPE-E)
Standard Compliance ISO 6722 Class D

Special properties

Limited resistance to hydrolysis

Technical Parameters

Operating temperature: –40 °C to +150 °C
Conductor Construction Insulation Cable
Nominal cross- section No. and Dia. of Wires Diameter of Conductor max. Electrical
resistance at 20°C
max.
Nominal thickness Overall Diameter Min. Overall Diameter Max. Weight approx.
mm2 No./mm mm mΩ/m mm mm mm kg/km
1x 0.35 12/0.21 0.9 52.0 0.20 1.2 1.4 5
1x 0. 5 16/0.21 1.0 37.1 0.22 1.4 1.6 6
1x 0. 75 24/0.21 1.2 24.7 0.24 1.7 1.9 9
1x1 32/0.21 1.35 18.5 0.24 1.9 2.1 12
1x 1.5 30/0.26 1.7 12.7 0.24 2.2 2.4 16
1x 2 30/0.31 2.0 9.42 0.28 2.5 2.8 23
1x 2.5 50/0.26 2.2 7.6 0.28 3.7 3.0 26
1x4 56/0.31 2.75 4.71 0.32 3.4 3.7 41
1x6 84/0.31 3.3 3.14 0.32 4.0 4.3 60

 

*Note: Other configurations, sizes, colors and length not specified herein are available upon request.