Germany Standard Automotive Cable
FLR31Y11Y
Applications
This TPE insulated low-tension automotive cable is used in motorcycles and other motor vehicles for starting, charging, lighting, signal and instrument panel circuits.
Construction
Conductor | Cu-ETP1 or bare according to DIN EN 13602 |
Insulation | TPE-S Outer |
Sheath | TPE-U |
Standard Compliance | ISO 6722 Class C |
Technical Parameters
Operating temperature: –40 °C to +125 °C
Special Properties
Flame retardant
Highly resistant against acids,lyes,petrol and diesel
Conductor Construction | Insulation | Cable | |||||||
Nominal cross- section | No. and Dia. of Wires | Diameter of Conductor max. | Electrical resistance at 20°C max. |
Nominal thickness | Diameter of core | Sheath wall thickness | Overall Diameter Min. | Overall Diameter Max. | Weight approx. |
mm2 | No./mm | mm | mΩ/m | mm | mm | mm | mm | mm | kg/km |
2x0.50 | 28/0.16 | 1.0 | 37.1 | 0.3 | 1.5 | 0.7 | 4.3 | 4.7 | 38 |
2x0.50 | 28/0.16 | 1.0 | 37.1 | 0.3 | 1.5 | 1.0 | 4.8 | 5.2 | 45 |
2x0.75 | 42/0.16 | 1.2 | 24.7 | 0.3 | 1.8 | 1.2 | 6.0 | 6.4 | 64 |
2x0.75 | 96/0.11 | 1.2 | 24.7 | 0.3 | 1.8 | 1.2 | 6.0 | 6.4 | 48 |
3x0.5 | 19/0.19 | 1.0 | 37.1 | 0.3 | 1.6 | 0.8 | 5.0 | 5.2 | 47 |
3x1.0 | 19/0.26 | 1.2 | 18.5 | 0.35 | 2.0 | 0.8 | 5.7 | 6. | 7 |
4x0.5 | 28/0.16 | 1.0 | 37. | 0.3 | 1.5 | 1.2 | 6.0 | 6.4 | 76 |
4x0.5 | 64/0. | 1.0 | 37. | 0.3 | 1.6 | 1.2 | 6.0 | 6.4 | 5 |
5x0.5 | 64/0. | 1.0 | 37. | 0.3 | 1.6 | 1.0 | 6.0 | 6.4 | 54 |
*Note: Other configurations, sizes, colors and length not specified herein are available upon request.