Germany Standard Automotive Cable
FLR5Y-B
Applications
This PTFE insulated low-tension automotive cable is used in motorcycles and other motor vehicles for starting , charging, lighting, signal and instrument panel circuits.
Construction
Conductor | Cu-ETP1 bare according to DIN EN13602 |
Insulation | PTFE |
Standard Compliance | ISO 6722 Class H |
Technical Parameters
Operating temperature: –90°C to +260°CSpecial properties
Excellent resistance to chemicals
Conductor Construction | Insulation | Cable | |||||
Nominal cross- section | No. and Dia. of Wires | Diameter of Conductor max. | Electrical resistance at 20°C max. |
Nominal thickness | Overall Diameter Min. | Overall Diameter Max. | Weight approx. |
mm2 | No./mm | mm | mΩ/m | mm | mm | mm | kg/km |
1x 0.35 | 12/0.21 | 0.9 | 87.9 | 0.20 | 1.25 | 1.35 | 5 |
1x 0. 5 | 16/0.21 | 1.0 | 56.8 | 0.22 | 1.4 | 1.6 | 6 |
1x 0. 75 | 24/0.21 | 1.2 | 38.6 | 0.24 | 1.7 | 1.9 | 9 |
1x1 | 32/0.21 | 1.4 | 25.7 | 0.24 | 1.75 | 1.95 | 11 |
1x 1.5 | 30/0.26 | 1.7 | 19.3 | 0.24 | 2.1 | 2.3 | 16 |
1x 2.5 | 50/0.26 | 2.2 | 13.2 | 0.28 | 2.5 | 2.8 | 26 |
1x 4 | 56/0.31 | 2.75 | 4.91 | 0.32 | 3.05 | 3.35 | 40 |
1x 6 | 84/0.31 | 3.4 | 3.27 | 0.32 | 3.85 | 4.15 | 61 |
*Note: Other configurations, sizes, colors and length not specified herein are available upon request.