Germany Standard Automotive Cable
FLRYDY
Applications
This PVC insulated low-tension automotive cable is used in motorcycles and other motor vehicles for starting, charging, lighting, signal and instrument panel circuits.
Construction
Conductor | Cu-ETP1 bare according to DIN EN13602 |
Insulation | PVC |
Screen | Copper wire spiral shield |
Sheath | PVC |
Standard Compliance | ISO 6722 Class B |
Special properties
Flame retardant
Flexible conductors with PVC thin wall insulation with increased mechanical strength
Technical Parameters
Operating temperature: –40°C to +105°CConductor Construction | Insulation | Cable | |||||||
Nominal cross- section | No. and Dia. of Wires | Diameter of Conductor max. | Electrical resistance at 20°C max. | Nominal thickness | Diameter of core | Sheath wall thickness | Overall Diameter Min. | Overall Diameter Max. | Weight approx. |
mm2 | No./mm | mm | mΩ/m | mm | mm | mm | mm | mm | kg/km |
1x075 | 24/0.21 | 1.2 | 24.7 | 0.3 | 1.75 | 0.3 | 2.5 | 2.7 | 20 |
1x1.00 | 32/0.21 | 1.35 | 18.5 | 0.3 | 1.95 | 0.3 | 2.7 | 2.9 | 23 |
1x1.50 | 30/0.26 | 1.7 | 12.7 | 0.3 | 2.25 | 0.3 | 3.0 | 3.2 | 29 |
*Note: Other configurations, sizes, colors and length not specified herein are available upon request.