American Standard Automotive Cable
GXL
Applications
This XLPE insulated single-core cable is used in automotive applications where higher heat resistance and small diameter is required.
Construction
Conductor | Soft-annealed copper according to ASTM B3 |
Insulation | Polyethylene crosslinked (XLPE) |
Standard Compliance | SAE J1128 |
Technical Parameters
Operating temperature: –40 °C to +125 °CConductor | Insulation | Cable | |||||
Size | Nominal Cross-section | No. and Dia. of Wires | Diameter max. | Thickness Wall min. | Thickness Wall nom. | Overall Diameter max. | Weight approx. |
AWG | mm2 | No./mm | mm | mm | mm | mm | kg/km |
20 | 1 x 0.50 | 19/0.20 | 0.97 | 0.41 | 0.58 | 2.40 | 9 |
18 | 1 x 0.80 | 19/0.23 | 1.17 | 0.41 | 0.58 | 2.50 | 12 |
18 | 1 x 0.80 | 16/0.25 | 1.17 | 0.41 | 0.58 | 2.50 | 12 |
16 | 1 x 1.00 | 19/0.24 | 1.45 | 0.41 | 0.58 | 2.90 | 17 |
14 | 1 x 2.00 | 19/0.36 | 1.80 | 0.41 | 0.58 | 3.20 | 25 |
12 | 1 x 3.00 | 19/0.45 | 2.29 | 0.46 | 0.66 | 3.80 | 38 |
10 | 1 x 5.00 | 19/0.57 | 2.87 | 0.56 | 0.79 | 4.70 | 58 |
*Note: Other configurations, sizes, colors and length not specified herein are available upon request.