0.6/1 kV CVV
IEC 60502 (2-30 core)

Conductor

Concentric Stranded copper wire

Insulation

PVC Black color

Identification

Printed White number on the surface of Black insulation

Filler

Suitable filler

Binding tape

Suitable tape

Sheath

PVC Black color

Application

For supervisory electrical equipment, station control circuits, outdoor, suitable installation in dry or wet cable trenches.

2 Core CVV Control Cable
3 Core CVV Control Cable
4 Core CVV Control Cable
5 Core CVV Control Cable
6 Core CVV Control Cable
7 Core CVV Control Cable
8 Core CVV Control Cable
9 Core CVV Control Cable
10 Core CVV Control Cable
11 Core CVV Control Cable
12 Core CVV Control Cable
13 Core CVV Control Cable
14 Core CVV Control Cable

15 Core CVV Control Cable
16 Core CVV Control Cable
17 Core CVV Control Cable
18 Core CVV Control Cable
19 Core CVV Control Cable
20 Core CVV Control Cable
21 Core CVV Control Cable
22 Core CVV Control Cable
23 Core CVV Control Cable
24 Core CVV Control Cable
25 Core CVV Control Cable
26 Core CVV Control Cable
27 Core CVV Control Cable
28 Core CVV Control Cable
29 Core CVV Control Cable
30 Core CVV Control Cable

2 Core CVV Control Cable

Part NO.

No. of core

Nominal
cross-
sectional area
sq.mm

No.& dia.
of wires No./mm

Thickness
of insulation mm

Thickness
of sheath
mm

Overall diameter (Approx.)
mm

Maximum conductor resistance
(at20C)
Ohm/km

Minimum insulation resistance
(at70C)
Ohm/km

Cable
weight (Approx.) kg/km

Standard Length
m

CCL-CT-CVV-2C0.50SQ

2

0.5

7/0.30

0.8

1.8

10.0

36.0

0.0162

98

500/D

CCL-CT-CVV-2C0.75SQ

0.75

7/0.37

0.8

1.8

10.0

24.5

0.0142

110

500/D

CCL-CT-CVV-2C1.00SQ

1

7/0.40

0.8

1.8

10.5

18.1

0.0135

115

500/D

CCL-CT-CVV-2C1.50SQ

1.5

7/0.50

0.8

1.8

11.0

12.1

0.0115

135

500/D

CCL-CT-CVV-2C2.50SQ

2.5

7/0.67

0.8

1.8

12.0

7.41

0.0093

180

500/D

CCL-CT-CVV-2C4.00SQ

4

7/0.85

1.0

1.8

14.5

4.61

0.0092

255

500/D

CCL-CT-CVV-2C6.00SQ

6

7/1.04

1.0

1.8

15.5

3.08

0.0078

320

500/D

3 Core CVV Control Cable

Part NO.

No. of core

Nominal
cross-
sectional area
sq.mm

No.& dia.
of wires No./mm

Thickness
of insulation mm

Thickness
of sheath
mm

Overall diameter (Approx.)
mm

Maximum conductor resistance
(at20C)
Ohm/km

Minimum insulation resistance
(at70C)
Ohm/km

Cable
weight (Approx.) kg/km

Standard Length
m

CCL-CT-CVV-3C0.50SQ

3

0.5

7/0.30

0.8

1.8

10.0

36.0

0.0162

110

500/D

CCL-CT-CVV-3C0.75SQ

0.75

7/0.37

0.8

1.8

10.5

24.5

0.0142

125

500/D

CCL-CT-CVV-3C1.00SQ

1

7/0.40

0.8

1.8

11.0

18.1

0.0135

135

500/D

CCL-CT-CVV-3C1.50SQ

1.5

7/0.50

0.8

1.8

11.5

12.1

0.0115

160

500/D

CCL-CT-CVV-3C2.50SQ

2.5

7/0.67

0.8

1.8

13.0

7.41

0.0093

220

500/D

CCL-CT-CVV-3C4.00SQ

4

7/0.85

1.0

1.8

15.0

4.61

0.0092

315

500/D

CCL-CT-CVV-3C6.00SQ

6

7/1.04

1.0

1.8

16.5

3.08

0.0078

405

500/D

4 Core CVV Control Cable

Part NO.

No. of core

Nominal
cross-
sectional area
sq.mm

No.& dia.
of wires No./mm

Thickness
of insulation mm

Thickness
of sheath
mm

Overall diameter (Approx.)
mm

Maximum conductor resistance
(at20C)
Ohm/km

Minimum insulation resistance
(at70C)
Ohm/km

Cable
weight (Approx.) kg/km

Standard Length
m

CCL-CT-CVV-4C0.50SQ

4

0.5

7/0.30

0.8

1.8

11.0

36.0

0.0162

130

500/D

CCL-CT-CVV-4C0.75SQ

0.75

7/0.37

0.8

1.8

11.5

24.5

0.0142

150

500/D

CCL-CT-CVV-4C1.00SQ

1

7/0.40

0.8

1.8

11.5

18.1

0.0135

160

500/D

CCL-CT-CVV-4C1.50SQ

1.5

7/0.50

0.8

1.8

12.5

12.1

0.0115

195

500/D

CCL-CT-CVV-4C2.50SQ

2.5

7/0.67

0.8

1.8

14.0

7.41

0.0093

265

500/D

CCL-CT-CVV-4C4.00SQ

4

7/0.85

1.0

1.8

16.5

4.61

0.0092

390

500/D

CCL-CT-CVV-4C6.00SQ

6

7/1.04

1.0

1.8

17.0

3.08

0.0078

510

500/D

5 Core CVV Control Cable

Part NO.

No. of core

Nominal
cross-
sectional area
sq.mm

No.& dia.
of wires No./mm

Thickness
of insulation mm

Thickness
of sheath
mm

Overall diameter (Approx.)
mm

Maximum conductor resistance
(at20C)
Ohm/km

Minimum insulation resistance
(at70C)
Ohm/km

Cable
weight (Approx.) kg/km

Standard Length
m

CCL-CT-CVV-5C0.50SQ

5

0.5

7/0.30

0.8

1.8

11.5

36.0

0.0162

150

500/D

CCL-CT-CVV-5C0.75SQ

0.75

7/0.37

0.8

1.8

12.5

24.5

0.0142

175

500/D

CCL-CT-CVV-5C1.00SQ

1

7/0.40

0.8

1.8

12.5

18.1

0.0135

190

500/D

CCL-CT-CVV-5C1.50SQ

1.5

7/0.50

0.8

1.8

13.5

12.1

0.0115

230

500/D

CCL-CT-CVV-5C2.50SQ

2.5

7/0.67

0.8

1.8

15.0

7.41

0.0093

320

500/D

CCL-CT-CVV-5C4.00SQ

4

7/0.85

1.0

1.8

18.0

4.61

0.0092

470

500/D

CCL-CT-CVV-5C6.00SQ

6

7/1.04

1.0

1.8

19.5

3.08

0.0078

620

500/D

6 Core CVV Control Cable

Part NO.

No. of core

Nominal
cross-
sectional area
sq.mm

No.& dia.
of wires No./mm

Thickness
of insulation mm

Thickness
of sheath
mm

Overall diameter (Approx.)
mm

Maximum conductor resistance
(at20C)
Ohm/km

Minimum insulation resistance
(at70C)
Ohm/km

Cable
weight (Approx.) kg/km

Standard Length
m

CCL-CT-CVV-6C0.50SQ

6

0.5

7/0.30

0.8

1.8

12.5

36.0

0.0162

165

500/D

CCL-CT-CVV-6C0.75SQ

0.75

7/0.37

0.8

1.8

13.0

24.5

0.0142

190

500/D

CCL-CT-CVV-6C1.00SQ

1

7/0.40

0.8

1.8

13.5

18.1

0.0135

205

500/D

CCL-CT-CVV-6C1.50SQ

1.5

7/0.50

0.8

1.8

14.5

12.1

0.0115

255

500/D

CCL-CT-CVV-6C2.50SQ

2.5

7/0.67

0.8

1.8

16.0

7.41

0.0093

355

500/D

CCL-CT-CVV-6C4.00SQ

4

7/0.85

1.0

1.8

19.5

4.61

0.0092

525

500/D

CCL-CT-CVV-6C6.00SQ

6

7/1.04

1.0

1.8

21.0

3.08

0.0078

690

500/D

7 Core CVV Control Cable

Part NO.

No. of core

Nominal
cross-
sectional area
sq.mm

No.& dia.
of wires No./mm

Thickness
of insulation mm

Thickness
of sheath
mm

Overall diameter (Approx.)
mm

Maximum conductor resistance
(at20C)
Ohm/km

Minimum insulation resistance
(at70C)
Ohm/km

Cable
weight (Approx.) kg/km

Standard Length
m

CCL-CT-CVV-7C0.50SQ

7

0.5

7/0.30

0.8

1.8

12.5

36.0

0.0162

170

500/D

CCL-CT-CVV-7C0.75SQ

0.75

7/0.37

0.8

1.8

13.0

24.5

0.0142

200

500/D

CCL-CT-CVV-7C1.00SQ

1

7/0.40

0.8

1.8

13.5

18.1

0.0135

215

500/D

CCL-CT-CVV-7C1.50SQ

1.5

7/0.50

0.8

1.8

14.5

12.1

0.0115

270

500/D

CCL-CT-CVV-7C2.50SQ

2.5

7/0.67

0.8

1.8

16.0

7.41

0.0093

380

500/D

CCL-CT-CVV-7C4.00SQ

4

7/0.85

1.0

1.8

19.5

4.61

0.0092

570

500/D

CCL-CT-CVV-7C6.00SQ

6

7/1.04

1.0

1.8

21.0

3.08

0.0078

795

500/D

8 Core CVV Control Cable

Part NO.

No. of core

Nominal
cross-
sectional area
sq.mm

No.& dia.
of wires No./mm

Thickness
of insulation mm

Thickness
of sheath
mm

Overall diameter (Approx.)
mm

Maximum conductor resistance
(at20C)
Ohm/km

Minimum insulation resistance
(at70C)
Ohm/km

Cable
weight (Approx.) kg/km

Standard Length
m

CCL-CT-CVV-8C0.50SQ

8

0.5

7/0.30

0.8

1.8

13.5

36.0

0.0162

195

500/D

CCL-CT-CVV-8C0.75SQ

0.75

7/0.37

0.8

1.8

14.0

24.5

0.0142

230

500/D

CCL-CT-CVV-8C1.00SQ

1

7/0.40

0.8

1.8

14.5

18.1

0.0135

250

500/D

CCL-CT-CVV-8C1.50SQ

1.5

7/0.50

0.8

1.8

15.5

12.1

0.0115

310

500/D

CCL-CT-CVV-8C2.50SQ

2.5

7/0.67

0.8

1.8

17.5

7.41

0.0093

440

500/D

CCL-CT-CVV-8C4.00SQ

4

7/0.85

1.0

1.8

21.0

4.61

0.0092

660

500/D

CCL-CT-CVV-8C6.00SQ

6

7/1.04

1.0

1.8

23.0

3.08

0.0078

875

500/D

9 Core CVV Control Cable

Part NO.

No. of core

Nominal
cross-
sectional area
sq.mm

No.& dia.
of wires No./mm

Thickness
of insulation mm

Thickness
of sheath
mm

Overall diameter (Approx.)
mm

Maximum conductor resistance
(at20C)
Ohm/km

Minimum insulation resistance
(at70C)
Ohm/km

Cable
weight (Approx.) kg/km

Standard Length
m

CCL-CT-CVV-9C0.50SQ

9

0.5

7/0.30

0.8

1.8

14.0

36.0

0.0162

220

500/D

CCL-CT-CVV-9C0.75SQ

0.75

7/0.37

0.8

1.8

15.0

24.5

0.0142

265

500/D

CCL-CT-CVV-9C1.00SQ

1

7/0.40

0.8

1.8

15.5

18.1

0.0135

285

500/D

CCL-CT-CVV-9C1.50SQ

1.5

7/0.50

0.8

1.8

16.5

12.1

0.0115

355

500/D

CCL-CT-CVV-9C2.50SQ

2.5

7/0.67

0.8

1.8

18.5

7.41

0.0093

505

500/D

CCL-CT-CVV-9C4.00SQ

4

7/0.85

1.0

1.8

22.5

4.61

0.0092

760

500/D

CCL-CT-CVV-9C6.00SQ

6

7/1.04

1.0

1.8

24.5

3.08

0.0078

1015

500/D

10 Core CVV Control Cable

Part NO.

No. of core

Nominal
cross-
sectional area
sq.mm

No.& dia.
of wires No./mm

Thickness
of insulation mm

Thickness
of sheath
mm

Overall diameter (Approx.)
mm

Maximum conductor resistance
(at20C)
Ohm/km

Minimum insulation resistance
(at70C)
Ohm/km

Cable
weight (Approx.) kg/km

Standard Length
m

CCL-CT-CVV-10C0.50SQ

10

0.5

7/0.30

0.8

1.8

15.5

36.0

0.0162

240

500/D

CCL-CT-CVV-10C0.75SQ

0.75

7/0.37

0.8

1.8

16.0

24.5

0.0142

285

500/D

CCL-CT-CVV-10C1.00SQ

1

7/0.40

0.8

1.8

16.5

18.1

0.0135

310

500/D

CCL-CT-CVV-10C1.50SQ

1.5

7/0.50

0.8

1.8

18.0

12.1

0.0115

385

500/D

CCL-CT-CVV-10C2.50SQ

2.5

7/0.67

0.8

1.8

20.0

7.41

0.0093

550

500/D

CCL-CT-CVV-10C4.00SQ

4

7/0.85

1.0

1.8

24.5

4.61

0.0092

825

500/D

CCL-CT-CVV-10C6.00SQ

6

7/1.04

1.0

1.8

27.0

3.08

0.0078

1100

500/D

11 Core CVV Control Cable

Part NO.

No. of core

Nominal
cross-
sectional area
sq.mm

No.& dia.
of wires No./mm

Thickness
of insulation mm

Thickness
of sheath
mm

Overall diameter (Approx.)
mm

Maximum conductor resistance
(at20C)
Ohm/km

Minimum insulation resistance
(at70C)
Ohm/km

Cable
weight (Approx.) kg/km

Standard Length
m

CCL-CT-CVV-11C0.50SQ

11

0.5

7/0.30

0.8

1.8

15.5

36.0

0.0162

255

500/D

CCL-CT-CVV-11C0.75SQ

0.75

7/0.37

0.8

1.8

16.5

24.5

0.0142

315

500/D

CCL-CT-CVV-11C1.00SQ

1

7/0.40

0.8

1.8

17.0

18.1

0.0135

340

500/D

CCL-CT-CVV-11C1.50SQ

1.5

7/0.50

0.8

1.8

18.5

12.1

0.0115

425

500/D

CCL-CT-CVV-11C2.50SQ

2.5

7/0.67

0.8

1.8

21.0

7.41

0.0093

605

500/D

CCL-CT-CVV-11C4.00SQ

4

7/0.85

1.0

1.8

25.0

4.61

0.0092

915

500/D

CCL-CT-CVV-11C6.00SQ

6

7/1.04

1.0

1.8

27.5

3.08

0.0078

1220

500/D

12 Core CVV Control Cable

Part NO.

No. of core

Nominal
cross-
sectional area
sq.mm

No.& dia.
of wires No./mm

Thickness
of insulation mm

Thickness
of sheath
mm

Overall diameter (Approx.)
mm

Maximum conductor resistance
(at20C)
Ohm/km

Minimum insulation resistance
(at70C)
Ohm/km

Cable
weight (Approx.) kg/km

Standard Length
m

CCL-CT-CVV-12C0.50SQ

12

0.5

7/0.30

0.8

1.8

15.5

36.0

0.0162

265

500/D

CCL-CT-CVV-12C0.75SQ

0.75

7/0.37

0.8

1.8

16.5

24.5

0.0142

320

500/D

CCL-CT-CVV-12C1.00SQ

1

7/0.40

0.8

1.8

17.0

18.1

0.0135

345

500/D

CCL-CT-CVV-12C1.50SQ

1.5

7/0.50

0.8

1.8

18.5

12.1

0.0115

440

500/D

CCL-CT-CVV-12C2.50SQ

2.5

7/0.67

0.8

1.8

21.0

7.41

0.0093

630

500/D

CCL-CT-CVV-12C4.00SQ

4

7/0.85

1.0

1.8

25.0

4.61

0.0092

950

500/D

CCL-CT-CVV-12C6.00SQ

6

7/1.04

1.0

1.8

27.5

3.08

0.0078

1270

500/D

13 Core CVV Control Cable

Part NO.

No. of core

Nominal
cross-
sectional area
sq.mm

No.& dia.
of wires No./mm

Thickness
of insulation mm

Thickness
of sheath
mm

Overall diameter (Approx.)
mm

Maximum conductor resistance
(at20C)
Ohm/km

Minimum insulation resistance
(at70C)
Ohm/km

Cable
weight (Approx.) kg/km

Standard Length
m

CCL-CT-CVV-13C0.50SQ

13

0.5

7/0.30

0.8

1.8

16.5

36.0

0.0162

295

500/D

CCL-CT-CVV-13C0.75SQ

0.75

7/0.37

0.8

1.8

17.5

24.5

0.0142

355

500/D

CCL-CT-CVV-13C1.00SQ

1

7/0.40

0.8

1.8

18.0

18.1

0.0135

380

500/D

CCL-CT-CVV-13C1.50SQ

1.5

7/0.50

0.8

1.8

19.5

12.1

0.0115

485

500/D

CCL-CT-CVV-13C2.50SQ

2.5

7/0.67

0.8

1.8

22.0

7.41

0.0093

695

500/D

CCL-CT-CVV-13C4.00SQ

4

7/0.85

1.0

1.8

26.5

4.61

0.0092

1050

500/D

CCL-CT-CVV-13C6.00SQ

6

7/1.04

1.0

1.8

29.0

3.08

0.0078

1405

500/D

14 Core CVV Control Cable

Part NO.

No. of core

Nominal
cross-
sectional area
sq.mm

No.& dia.
of wires No./mm

Thickness
of insulation mm

Thickness
of sheath
mm

Overall diameter (Approx.)
mm

Maximum conductor resistance
(at20C)
Ohm/km

Minimum insulation resistance
(at70C)
Ohm/km

Cable
weight (Approx.) kg/km

Standard Length
m

CCL-CT-CVV-14C0.50SQ

14

0.5

7/0.30

0.8

1.8

16.5

36.0

0.0162

300

500/D

CCL-CT-CVV-14C0.75SQ

0.75

7/0.37

0.8

1.8

17.5

24.5

0.0142

360

500/D

CCL-CT-CVV-14C1.00SQ

1

7/0.40

0.8

1.8

18.0

18.1

0.0135

390

500/D

CCL-CT-CVV-14C1.50SQ

1.5

7/0.50

0.8

1.8

19.5

12.1

0.0115

495

500/D

CCL-CT-CVV-14C2.50SQ

2.5

7/0.67

0.8

1.8

22.0

7.41

0.0093

715

500/D

CCL-CT-CVV-14C4.00SQ

4

7/0.85

1.0

1.8

26.5

4.61

0.0092

1085

500/D

CCL-CT-CVV-14C6.00SQ

6

7/1.04

1.0

1.8

29.0

3.08

0.0078

1455

500/D

15 Core CVV Control Cable

Part NO.

No. of core

Nominal
cross-
sectional area
sq.mm

No.& dia.
of wires No./mm

Thickness
of insulation mm

Thickness
of sheath
mm

Overall diameter (Approx.)
mm

Maximum conductor resistance
(at20C)
Ohm/km

Minimum insulation resistance
(at70C)
Ohm/km

Cable
weight (Approx.) kg/km

Standard Length
m

CCL-CT-CVV-15C0.50SQ

15

0.5

7/0.30

0.8

1.8

17.0

36.0

0.0162

330

500/D

CCL-CT-CVV-15C0.75SQ

0.75

7/0.37

0.8

1.8

18.5

24.5

0.0142

395

500/D

CCL-CT-CVV-15C1.00SQ

1

7/0.40

0.8

1.8

19.0

18.1

0.0135

425

500/D

CCL-CT-CVV-15C1.50SQ

1.5

7/0.50

0.8

1.8

20.5

12.1

0.0115

545

500/D

CCL-CT-CVV-15C2.50SQ

2.5

7/0.67

0.8

1.8

23.0

7.41

0.0093

785

500/D

CCL-CT-CVV-15C4.00SQ

4

7/0.85

1.0

1.8

28.0

4.61

0.0092

1195

500/D

CCL-CT-CVV-15C6.00SQ

6

7/1.04

1.0

1.8

31.0

3.08

0.0078

1600

500/D

16 Core CVV Control Cable

Part NO.

No. of core

Nominal
cross-
sectional area
sq.mm

No.& dia.
of wires No./mm

Thickness
of insulation mm

Thickness
of sheath
mm

Overall diameter (Approx.)
mm

Maximum conductor resistance
(at20C)
Ohm/km

Minimum insulation resistance
(at70C)
Ohm/km

Cable
weight (Approx.) kg/km

Standard Length
m

CCL-CT-CVV-16C0.50SQ

16

0.5

7/0.30

0.8

1.8

17.0

36.0

0.0162

330

500/D

CCL-CT-CVV-16C0.75SQ

0.75

7/0.37

0.8

1.8

18.5

24.5

0.0142

400

500/D

CCL-CT-CVV-16C1.00SQ

1

7/0.40

0.8

1.8

19.0

18.1

0.0135

435

500/D

CCL-CT-CVV-16C1.50SQ

1.5

7/0.50

0.8

1.8

20.5

12.1

0.0115

555

500/D

CCL-CT-CVV-16C2.50SQ

2.5

7/0.67

0.8

1.8

23.0

7.41

0.0093

805

500/D

CCL-CT-CVV-16C4.00SQ

4

7/0.85

1.0

1.8

28.0

4.61

0.0092

1230

500/D

CCL-CT-CVV-16C6.00SQ

6

7/1.04

1.0

1.8

31.0

3.08

0.0078

1650

500/D

17 Core CVV Control Cable

Part NO.

No. of core

Nominal
cross-
sectional area
sq.mm

No.& dia.
of wires No./mm

Thickness
of insulation mm

Thickness
of sheath
mm

Overall diameter (Approx.)
mm

Maximum conductor resistance
(at20C)
Ohm/km

Minimum insulation resistance
(at70C)
Ohm/km

Cable
weight (Approx.) kg/km

Standard Length
m

CCL-CT-CVV-17C0.50SQ

17

0.5

7/0.30

0.8

1.8

18.0

36.0

0.0162

355

500/D

CCL-CT-CVV-17C0.75SQ

0.75

7/0.37

0.8

1.8

19.0

24.5

0.0142

430

500/D

CCL-CT-CVV-17C1.00SQ

1

7/0.40

0.8

1.8

19.5

18.1

0.0135

465

500/D

CCL-CT-CVV-17C1.50SQ

1.5

7/0.50

0.8

1.8

21.5

12.1

0.0115

595

500/D

CCL-CT-CVV-17C2.50SQ

2.5

7/0.67

0.8

1.8

24.0

7.41

0.0093

865

500/D

CCL-CT-CVV-17C4.00SQ

4

7/0.85

1.0

1.8

29.5

4.61

0.0092

1315

500/D

CCL-CT-CVV-17C6.00SQ

6

7/1.04

1.0

1.9

32.5

3.08

0.0078

1785

500/D

18 Core CVV Control Cable

Part NO.

No. of core

Nominal
cross-
sectional area
sq.mm

No.& dia.
of wires No./mm

Thickness
of insulation mm

Thickness
of sheath
mm

Overall diameter (Approx.)
mm

Maximum conductor resistance
(at20C)
Ohm/km

Minimum insulation resistance
(at70C)
Ohm/km

Cable
weight (Approx.) kg/km

Standard Length
m

CCL-CT-CVV-18C0.50SQ

18

0.5

7/0.30

0.8

1.8

18.0

36.0

0.0162

360

500/D

CCL-CT-CVV-18C0.75SQ

0.75

7/0.37

0.8

1.8

19.0

24.5

0.0142

435

500/D

CCL-CT-CVV-18C1.00SQ

1

7/0.40

0.8

1.8

19.5

18.1

0.0135

475

500/D

CCL-CT-CVV-18C1.50SQ

1.5

7/0.50

0.8

1.8

21.5

12.1

0.0115

605

500/D

CCL-CT-CVV-18C2.50SQ

2.5

7/0.67

0.8

1.8

24.0

7.41

0.0093

885

500/D

CCL-CT-CVV-18C4.00SQ

4

7/0.85

1.0

1.8

29.5

4.61

0.0092

1350

500/D

CCL-CT-CVV-18C6.00SQ

6

7/1.04

1.0

1.9

32.5

3.08

0.0078

1835

500/D

19 Core CVV Control Cable

Part NO.

No. of core

Nominal
cross-
sectional area
sq.mm

No.& dia.
of wires No./mm

Thickness
of insulation mm

Thickness
of sheath
mm

Overall diameter (Approx.)
mm

Maximum conductor resistance
(at20C)
Ohm/km

Minimum insulation resistance
(at70C)
Ohm/km

Cable
weight (Approx.) kg/km

Standard Length
m

CCL-CT-CVV-19C0.50SQ

19

0.5

7/0.30

0.8

1.8

18.0

36.0

0.0162

365

500/D

CCL-CT-CVV-19C0.75SQ

0.75

7/0.37

0.8

1.8

19.0

24.5

0.0142

445

500/D

CCL-CT-CVV-19C1.00SQ

1

7/0.40

0.8

1.8

19.5

18.1

0.0135

480

500/D

CCL-CT-CVV-19C1.50SQ

1.5

7/0.50

0.8

1.8

21.5

12.1

0.0115

620

500/D

CCL-CT-CVV-19C2.50SQ

2.5

7/0.67

0.8

1.8

24.0

7.41

0.0093

905

500/D

CCL-CT-CVV-19C4.00SQ

4

7/0.85

1.0

1.8

29.5

4.61

0.0092

1385

500/D

CCL-CT-CVV-19C6.00SQ

6

7/1.04

1.0

1.9

32.5

3.08

0.0078

1885

500/D

20 Core CVV Control Cable

Part NO.

No. of core

Nominal
cross-
sectional area
sq.mm

No.& dia.
of wires No./mm

Thickness
of insulation mm

Thickness
of sheath
mm

Overall diameter (Approx.)
mm

Maximum conductor resistance
(at20C)
Ohm/km

Minimum insulation resistance
(at70C)
Ohm/km

Cable
weight (Approx.) kg/km

Standard Length
m

CCL-CT-CVV-20C0.50SQ

20

0.5

7/0.30

0.8

1.8

19.0

36.0

0.0162

390

500/D

CCL-CT-CVV-20C0.75SQ

0.75

7/0.37

0.8

1.8

20.0

24.5

0.0142

475

500/D

CCL-CT-CVV-20C1.00SQ

1

7/0.40

0.8

1.8

20.5

18.1

0.0135

515

500/D

CCL-CT-CVV-20C1.50SQ

1.5

7/0.50

0.8

1.8

22.5

12.1

0.0115

665

500/D

CCL-CT-CVV-20C2.50SQ

2.5

7/0.67

0.8

1.8

25.5

7.41

0.0093

975

500/D

CCL-CT-CVV-20C4.00SQ

4

7/0.85

1.0

1.8

31.0

4.61

0.0092

1490

500/D

CCL-CT-CVV-20C6.00SQ

6

7/1.04

1.0

2.0

34.5

3.08

0.0078

2040

500/D

21 Core CVV Control Cable

Part NO.

No. of core

Nominal
cross-
sectional area
sq.mm

No.& dia.
of wires No./mm

Thickness
of insulation mm

Thickness
of sheath
mm

Overall diameter (Approx.)
mm

Maximum conductor resistance
(at20C)
Ohm/km

Minimum insulation resistance
(at70C)
Ohm/km

Cable
weight (Approx.) kg/km

Standard Length
m

CCL-CT-CVV-21C0.50SQ

21

0.5

7/0.30

0.8

1.8

19.0

36.0

0.0162

400

500/D

CCL-CT-CVV-21C0.75SQ

0.75

7/0.37

0.8

1.8

20.0

24.5

0.0142

490

500/D

CCL-CT-CVV-21C1.00SQ

1

7/0.40

0.8

1.8

20.5

18.1

0.0135

530

500/D

CCL-CT-CVV-21C1.50SQ

1.5

7/0.50

0.8

1.8

22.5

12.1

0.0115

685

500/D

CCL-CT-CVV-21C2.50SQ

2.5

7/0.67

0.8

1.8

25.5

7.41

0.0093

1005

500/D

CCL-CT-CVV-21C4.00SQ

4

7/0.85

1.0

1.8

31.0

4.61

0.0092

1540

500/D

CCL-CT-CVV-21C6.00SQ

6

7/1.04

1.0

2.0

34.5

3.08

0.0078

2040

500/D

22 Core CVV Control Cable

Part NO.

No. of core

Nominal
cross-
sectional area
sq.mm

No.& dia.
of wires No./mm

Thickness
of insulation mm

Thickness
of sheath
mm

Overall diameter (Approx.)
mm

Maximum conductor resistance
(at20C)
Ohm/km

Minimum insulation resistance
(at70C)
Ohm/km

Cable
weight (Approx.) kg/km

Standard Length
m

CCL-CT-CVV-22C0.50SQ

22

0.5

7/0.30

0.8

1.8

20.0

36.0

0.0162

430

500/D

CCL-CT-CVV-22C0.75SQ

0.75

7/0.37

0.8

1.8

21.0

24.5

0.0142

520

500/D

CCL-CT-CVV-22C1.00SQ

1

7/0.40

0.8

1.8

21.5

18.1

0.0135

565

500/D

CCL-CT-CVV-22C1.50SQ

1.5

7/0.50

0.8

1.8

23.5

12.1

0.0115

730

500/D

CCL-CT-CVV-22C2.50SQ

2.5

7/0.67

0.8

1.8

265

7.41

0.0093

1070

500/D

CCL-CT-CVV-22C4.00SQ

4

7/0.85

1.0

1.9

32.5

4.61

0.0092

1655

500/D

CCL-CT-CVV-22C6.00SQ

6

7/1.04

1.0

2.0

36.5

3.08

0.0078

2245

500/D

23 Core CVV Control Cable

Part NO.

No. of core

Nominal
cross-
sectional area
sq.mm

No.& dia.
of wires No./mm

Thickness
of insulation mm

Thickness
of sheath
mm

Overall diameter (Approx.)
mm

Maximum conductor resistance
(at20C)
Ohm/km

Minimum insulation resistance
(at70C)
Ohm/km

Cable
weight (Approx.) kg/km

Standard Length
m

CCL-CT-CVV-23C0.50SQ

23

0.5

7/0.30

0.8

1.8

19.5

36.0

0.0162

440

500/D

CCL-CT-CVV-23C0.75SQ

0.75

7/0.37

0.8

1.8

21.0

24.5

0.0142

540

500/D

CCL-CT-CVV-23C1.00SQ

1

7/0.40

0.8

1.8

21.5

18.1

0.0135

585

500/D

CCL-CT-CVV-23C1.50SQ

1.5

7/0.50

0.8

1.8

23.5

12.1

0.0115

755

500/D

CCL-CT-CVV-23C2.50SQ

2.5

7/0.67

0.8

1.8

26.5

7.41

0.0093

1105

500/D

CCL-CT-CVV-23C4.00SQ

4

7/0.85

1.0

1.9

32.5

4.61

0.0092

1710

500/D

CCL-CT-CVV-23C6.00SQ

6

7/1.04

1.0

2.0

36.5

3.08

0.0078

2330

500/D

24 Core CVV Control Cable

Part NO.

No. of core

Nominal
cross-
sectional area
sq.mm

No.& dia.
of wires No./mm

Thickness
of insulation mm

Thickness
of sheath
mm

Overall diameter (Approx.)
mm

Maximum conductor resistance
(at20C)
Ohm/km

Minimum insulation resistance
(at70C)
Ohm/km

Cable
weight (Approx.) kg/km

Standard Length
m

CCL-CT-CVV-24C0.50SQ

24

0.5

7/0.30

0.8

1.8

21.0

36.0

0.0162

460

500/D

CCL-CT-CVV-24C0.75SQ

0.75

7/0.37

0.8

1.8

22.0

24.5

0.0142

560

500/D

CCL-CT-CVV-24C1.00SQ

1

7/0.40

0.8

1.8

23.0

18.1

0.0135

605

500/D

CCL-CT-CVV-24C1.50SQ

1.5

7/0.50

0.8

1.8

24.5

12.1

0.0115

785

500/D

CCL-CT-CVV-24C2.50SQ

2.5

7/0.67

0.8

1.8

28.0

7.41

0.0093

1150

500/D

CCL-CT-CVV-24C4.00SQ

4

7/0.85

1.0

2.0

34.5

4.61

0.0092

1795

500/D

CCL-CT-CVV-24C6.00SQ

6

7/1.04

1.0

2.0

36.5

3.08

0.0078

2330

500/D

25 Core CVV Control Cable

Part NO.

No. of core

Nominal
cross-
sectional area
sq.mm

No.& dia.
of wires No./mm

Thickness
of insulation mm

Thickness
of sheath
mm

Overall diameter (Approx.)
mm

Maximum conductor resistance
(at20C)
Ohm/km

Minimum insulation resistance
(at70C)
Ohm/km

Cable
weight (Approx.) kg/km

Standard Length
m

CCL-CT-CVV-25C0.50SQ

25

0.5

7/0.30

0.8

1.8

21.0

36.0

0.0162

490

500/D

CCL-CT-CVV-25C0.75SQ

0.75

7/0.37

0.8

1.8

22.5

24.5

0.0142

595

500/D

CCL-CT-CVV-25C1.00SQ

1

7/0.40

0.8

1.8

23.0

18.1

0.0135

645

500/D

CCL-CT-CVV-25C1.50SQ

1.5

7/0.50

0.8

1.8

25.5

12.1

0.0115

835

500/D

CCL-CT-CVV-25C2.50SQ

2.5

7/0.67

0.8

1.8

28.5

7.41

0.0093

1225

500/D

CCL-CT-CVV-25C4.00SQ

4

7/0.85

1.0

2.0

35.5

4.61

0.0092

1915

500/D

CCL-CT-CVV-25C6.00SQ

6

7/1.04

1.0

2.1

39.5

3.08

0.0078

2595

500/D

26 Core CVV Control Cable

Part NO.

No. of core

Nominal
cross-
sectional area
sq.mm

No.& dia.
of wires No./mm

Thickness
of insulation mm

Thickness
of sheath
mm

Overall diameter (Approx.)
mm

Maximum conductor resistance
(at20C)
Ohm/km

Minimum insulation resistance
(at70C)
Ohm/km

Cable
weight (Approx.) kg/km

Standard Length
m

CCL-CT-CVV-27C0.50SQ

27

0.5

7/0.30

0.8

1.8

21.0

36.0

0.0162

500

500/D

CCL-CT-CVV-27C0.75SQ

0.75

7/0.37

0.8

1.8

22.5

24.5

0.0142

610

500/D

CCL-CT-CVV-27C1.00SQ

1

7/0.40

0.8

1.8

23.0

18.1

0.0135

665

500/D

CCL-CT-CVV-27C1.50SQ

1.5

7/0.50

0.8

1.8

25.5

12.1

0.0115

860

500/D

CCL-CT-CVV-27C2.50SQ

2.5

7/0.67

0.8

1.8

28.5

7.41

0.0093

1270

500/D

CCL-CT-CVV-27C4.00SQ

4

7/0.85

1.0

2.0

35.5

4.61

0.0092

1985

500/D

CCL-CT-CVV-27C6.00SQ

6

7/1.04

1.0

2.1

39.5

3.08

0.0078

2700

500/D

27 Core CVV Control Cable

Part NO.

No. of core

Nominal
cross-
sectional area
sq.mm

No.& dia.
of wires No./mm

Thickness
of insulation mm

Thickness
of sheath
mm

Overall diameter (Approx.)
mm

Maximum conductor resistance
(at20C)
Ohm/km

Minimum insulation resistance
(at70C)
Ohm/km

Cable
weight (Approx.) kg/km

Standard Length
m

CCL-CT-CVV-27C0.50SQ

27

0.5

7/0.30

0.8

1.8

21.0

36.0

0.0162

500

500/D

CCL-CT-CVV-27C0.75SQ

0.75

7/0.37

0.8

1.8

22.5

24.5

0.0142

610

500/D

CCL-CT-CVV-27C1.00SQ

1

7/0.40

0.8

1.8

23.0

18.1

0.0135

665

500/D

CCL-CT-CVV-27C1.50SQ

1.5

7/0.50

0.8

1.8

25.5

12.1

0.0115

860

500/D

CCL-CT-CVV-27C2.50SQ

2.5

7/0.67

0.8

1.8

28.5

7.41

0.0093

1270

500/D

CCL-CT-CVV-27C4.00SQ

4

7/0.85

1.0

2.0

35.5

4.61

0.0092

1985

500/D

CCL-CT-CVV-27C6.00SQ

6

7/1.04

1.0

2.1

39.5

3.08

0.0078

2700

500/D

28 Core CVV Control Cable

Part NO.

No. of core

Nominal
cross-
sectional area
sq.mm

No.& dia.
of wires No./mm

Thickness
of insulation mm

Thickness
of sheath
mm

Overall diameter (Approx.)
mm

Maximum conductor resistance
(at20C)
Ohm/km

Minimum insulation resistance
(at70C)
Ohm/km

Cable
weight (Approx.) kg/km

Standard Length
m

CCL-CT-CVV-28C0.50SQ

28

0.5

7/0.30

0.8

1.8

22.0

36.0

0.0162

535

500/D

CCL-CT-CVV-28C0.75SQ

0.75

7/0.37

0.8

1.8

23.5

24.5

0.0142

650

500/D

CCL-CT-CVV-28C1.00SQ

1

7/0.40

0.8

1.8

24.0

18.1

0.0135

710

500/D

CCL-CT-CVV-28C1.50SQ

1.5

7/0.50

0.8

1.8

26.0

12.1

0.0115

915

500/D

CCL-CT-CVV-28C2.50SQ

2.5

7/0.67

0.8

1.8

30.0

7.41

0.0093

1350

500/D

CCL-CT-CVV-28C4.00SQ

4

7/0.85

1.0

2.0

37.0

4.61

0.0092

2110

500/D

CCL-CT-CVV-28C6.00SQ

6

7/1.04

1.0

2.2

41.5

3.08

0.0078

2885

500/D

29 Core CVV Control Cable

Part NO.

No. of core

Nominal
cross-
sectional area
sq.mm

No.& dia.
of wires No./mm

Thickness
of insulation mm

Thickness
of sheath
mm

Overall diameter (Approx.)
mm

Maximum conductor resistance
(at20C)
Ohm/km

Minimum insulation resistance
(at70C)
Ohm/km

Cable
weight (Approx.) kg/km

Standard Length
m

CCL-CT-CVV-29C0.50SQ

29

0.5

7/0.30

0.8

1.8

22.0

36.0

0.0162

540

500/D

CCL-CT-CVV-29C0.75SQ

0.75

7/0.37

0.8

1.8

23.5

24.5

0.0142

660

500/D

CCL-CT-CVV-29C1.00SQ

1

7/0.40

0.8

1.8

24.0

18.1

0.0135

715

500/D

CCL-CT-CVV-29C1.50SQ

1.5

7/0.50

0.8

1.8

26.0

12.1

0.0115

930

500/D

CCL-CT-CVV-29C2.50SQ

2.5

7/0.67

0.8

1.8

30.0

7.41

0.0093

1370

500/D

CCL-CT-CVV-29C4.00SQ

4

7/0.85

1.0

2.0

37.0

4.61

0.0092

2145

500/D

CCL-CT-CVV-29C6.00SQ

6

7/1.04

1.0

2.2

41.5

3.08

0.0078

2940

500/D

30 Core CVV Control Cable

Part NO.

No. of core

Nominal
cross-
sectional area
sq.mm

No.& dia.
of wires No./mm

Thickness
of insulation mm

Thickness
of sheath
mm

Overall diameter (Approx.)
mm

Maximum conductor resistance
(at20C)
Ohm/km

Minimum insulation resistance
(at70C)
Ohm/km

Cable
weight (Approx.) kg/km

Standard Length
m

CCL-CT-CVV-30C0.50SQ

30

0.5

7/0.30

0.8

1.8

22.0

36.0

0.0162

540

500/D

CCL-CT-CVV-30C0.75SQ

0.75

7/0.37

0.8

1.8

23.0

24.5

0.0142

665

500/D

CCL-CT-CVV-30C1.00SQ

1

7/0.40

0.8

1.8

24.0

18.1

0.0135

725

500/D

CCL-CT-CVV-30C1.50SQ

1.5

7/0.50

0.8

1.8

26.0

12.1

0.0115

940

500/D

CCL-CT-CVV-30C2.50SQ

2.5

7/0.67

0.8

1.8

30.0

7.41

0.0093

1395

500/D

CCL-CT-CVV-30C4.00SQ

4

7/0.85

1.0

2.0

37.0

4.61

0.0092

2180

500/D

CCL-CT-CVV-30C6.00SQ

6

7/1.04

1.0

2.2

41.5

3.08

0.0078

2990

500/D

 

The table of 0.6/1 KV CVV shown concentric stranded conductor only. If you want to have solid or flexible conductor type, please contact with our Sales Department.