British Standard Highway Cables
Loop Detector Cable to BS6500 and BS6195
Application and Description
Loop Detector Cable is used to measure and control traffic flow. Typical applications are for traffic control signals, safety cameras, variable speed control systems, flow monitoring and access control.
Standard and Approval
BS 6500, BS6195, BS 6360, BS 7655
Cable Construction
- Conductor: Stranded tinned copper, comply with BS 6360, Class 5 |
Technical Characteristics
- Rated voltage: 450/750 volts
- Conductor Resistance at 20°C: 13.7ohms/km(1.5mm2};
8.21 ohms/km(2.5mm2)
- Minimum bending radius: 6 x O
- Temperature range: -30o C - +85o C
Cable Parameter
Number of Cores | Nominal Conductor Area | Nominal Conductor Stranding | Insulation Thickness | Sheath Thickness | Nominal O/D | Approx Cable Weight |
mm2 | NO./mm | mm | mm | mm | Kg/km | |
1 | 1.5 | 30/0.25 | 0.8 | 1.4 | 7.2 | 53.8 |
1 | 2.5 | 50/0.25 | 2.1 | - | 6.4 | 62.8 |