Rolling Stock Cables

RSE/STD/024 PART 6

RSE/STD/024 Part 6 Rolling Stock Cable

300/500V Multipair RSE/STD/024 Part 6 Rolling Stock Type Ⅷ screened Cable, with jacket

Cross- sectional Area

0.5mm2-1.0mm2

Voltage rating

30/50V

Conductor

Flexible Stranded Tinned Copper

Number of pairs

1,2,3

Conductor class

IEC 60228 Class 5

Screen

Copper Braid Screen

Insulation

Cross linked EPR rubber type EI 107, Standard wale

Jacket

Cross linked EVA rubber type EM 104

Fire standard

IEC 332-3C,IEC754;IEC1034-1/2


No. of Pairs

Cross Sectional Area

(mm2)

Number and Nominal Diameter of Strands

(mm)

Voltage Rating

(V)

Nominal Overall
Diameter

(mm)

Nominal Weight

(kg/km)

1 Pair

0.5

16/0.2

30/50

8.45

99.0

1 Pair

0.75

24/0.2

30/50

9.2

110.0

1 Pair

1.0

32/0.2

30/50

9.5

139.0

1 Pair

1.0

32/0.2

30/50

11.7

186.0

1 Pair

1.0

32/0.2

30/50

15.6

306.0

2 Pair

1.0

32/0.2

30/50

15.7

443.0

3 Pair

1.0

32/0.2

30/50

21.7

662.0

300/500V Multipair RSE/STD/024 Part 6 Rolling StockType Ⅸ screened Cable, with jacket

Cross- sectional Area

0.5mm2-1.0mm2

Voltage rating

300/500V

Conductor

Flexible Stranded Tinned Copper

Number of pairs

1,2,3,4

Conductor class

19/37 AWG Stranding

Insulation

Cross linked EPR rubber type EI 107, Reduced Wall

Screen

Copper Braid Screen

Jacket

Cross linked EVA rubber type EM 104

Fire standard

IEC 332-3C,IEC754;IEC1034-1/2


No. of Pairs

Cross Sectional Area

(mm2)

Number and Nominal Diameter of Strands

(mm)

Voltage Rating

(V)

Nominal Overall
Diameter

(mm)

Nominal Weight

(kg/km)

1 Pair

0.5

19/0.18

30/50

6.1

57.0

2 Pair

0.5

19/0.18

30/50

10.2

110.0

1 Pair

1.0

37/0.18

30/50

7.0

85.0

2 Pair

1.0

37/0.18

30/50

12.2

187.5

3 Pair

1.0

37/0.18

30/50

12.9

217.0

4 Pair

1.0

37/0.18

30/50

14.0

290.0

600/1000V Singlecore RSE/STD/024 Part 6 Rolling Stock TypeⅠCable, unsheathed

Cross-sectional Area

0.5mm2-4mm2

Voltage rating

600/1000V

Conductor

Flexible Stranded Tinned Copper

Number of cores

1

Conductor class

19/37 AWG Stranding

Insulation

Cross linked EPR rubber type EI 107 Reduced wall

Fire standard

IEC 332-3C,IEC754;IEC1034-1/2


No. of Cores

Cross Sectional Area

(mm2)

Number and Nominal Diameter of Strands

(mm)

Voltage Rating

(V)

Nominal Overall
Diameter

(mm)

Nominal Weight

(kg/km)

singlecore

0.5

19/0.18

600/1000

1.5

5.9

singlecore

0.75

37/0.16

600/1000

1.76

8.7

singlecore

1.0

37/0.18

600/1000

1.9

10.7

singlecore

1.5

37/0.23

600/1000

2.25

16.5

singlecore

2.5

37/0.3

600/1000

2.84

28.0

singlecore

4.0

37/0.37

600/1000

3.44

42.0

600/1000V Singlecore RSE/STD/024 Part 6 Rolling StockType Ⅱ Cable, unsheathed

Cross- sectional Area

0.75mm2-300mm2

Voltage rating

600/1000V

Conductor

Flexible Stranded Tinned Copper

Number of cores

1

Conductor class

IEC 60228 Class 5

Insulation

Cross linked EPR rubber type EI 107, Standard Wall

Fire standard

IEC 332-3C,IEC754;IEC1034-1/2


No. of Cores/Pairs

Cross Sectional Area

(mm2)

Number and Nominal Diameter of Strands

(mm)

Voltage Rating

(V)

Nominal Overall
Diameter

(mm)

Nominal Weight

(kg/km)

singlecore

0.75

24/0.2

600/1000

2.99

14.9

singlecore

1.0

32/0.2

600/1000

3.3

19.2

singlecore

1.5

30/0.25

600/1000

3.69

26.3

singlecore

2.5

50/0.25

600/1000

4.16

37.8

singlecore

4.0

56/0.3

600/1000

4.95

56.6

singlecore

6.0

84/0.3

600/1000

5.55

80.4

singlecore

10.0

80/0.4

600/1000

7.0

135.0

singlecore

16.0

128.4

600/1000

8.35

201.8

singlecore

25.0

196/0.4

600/1000

10.2

3.9.3

singlecore

35.0

2/6/0.4

600/1000

11.75

404.1

singlecore

50.0

396/0.4

600/1000

13.7

562.0

singlecore

70.0

360/0.5

600/1000

16.25

768.0

singlecore

95.0

476/0.6

600/1000

18.05

1002.8

singlecore

150.0

756/0.5

600/1000

22.95

1583.0

singlecore

240.0

1221/0.5

600/1000

27.9

2516.0

singlecore

300.0

1525/0.5

600/1000

31.35

3089.0

                                                                                   1      2      3